Showing
1 - 25
of 414
Compare
Mfr Part #
Price
Stock
Supplier
Mfr
Min Qty
DK Part #
Series
Package
Part Status
Type
Input Range
Output
Isolation
Response Time
Accuracy
Voltage - Supply
Mounting Type
Termination Style
Operating Temperature
Approval Agency
IsoBlock V-1C
TRANSDUCER VOLTAGE 9-28VDC
$416.30000
54 - Immediate
Verivolt LLCVerivolt LLC
1
1780-1057-ND
IsoBlock V
Box
ActiveVoltage Transducer±1000V±5V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
2308027
TRANSDUCER CURRENT 24VDC
$444.76000
38 - Immediate
Phoenix ContactPhoenix Contact
1
277-14602-ND
MCR
Bulk
ActiveCurrent Transducer0 ~ 200A4 ~ 20mA300VAC (Working), 3500VAC (Test)150ms-24VDCChassis Mount, DIN RailSpring Terminal-40°C ~ 65°CCE, cULus
CR4510-500
TRANSDUCER VOLTAGE 24VDC
$235.89000
32 - Immediate
CR Magnetics Inc.CR Magnetics Inc.
1
582-1184-ND
CR4500
Box
ActiveTrue RMS AC Voltage Transducer0 ~ 500VAC0 ~ 5VDC2500VDC250ms0.5%24VDCDIN RailScrew Terminal0°C ~ 60°CCE, cURus
IsoBlock I-FG-1C
TRANSDUCER CURRENT 9-28VDC
$264.18000
21 - Immediate
Verivolt LLCVerivolt LLC
1
1780-1008-ND
IsoBlock I-FG
Box
ActiveCurrent Transducer0 ~ 6A±10V1200V (Working)5µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
2906242
TRANSDUCER VOLTAGE 24VDC
$549.50000
19 - Immediate
Phoenix ContactPhoenix Contact
1
277-12214-ND
MACX
Bulk
ActiveVoltage Transducer±660VDC±10V5300VAC (Test)16ms-24VDCDIN RailScrew Terminal-25°C ~ 60°CCE, cULus
2814715
TRANSDUCER CURRENT 20-30VDC
$649.72000
18 - Immediate
139 - Factory
Phoenix ContactPhoenix Contact
1
277-4888-ND
MCR
Bulk
ActiveCurrent Transducer0 ~ 11A±10VDC, 0 ~ 20mA300VAC (Working), 4000VAC (Test)40ms, 330ms-20 ~ 30VDCDIN RailScrew Terminal-20°C ~ 60°CCE, cULus
IsoBlock V-4C
TRANSDUCER VOLTAGE 9-28VDC
$1,392.99000
8 - Immediate
Verivolt LLCVerivolt LLC
1
1780-1035-ND
IsoBlock V
Box
ActiveVoltage Transducer±100V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock V-4C
TRANSDUCER VOLTAGE 9-28VDC
$1,392.99000
2 - Immediate
Verivolt LLCVerivolt LLC
1
1780-1031-ND
IsoBlock V
Box
ActiveVoltage Transducer±500V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
CR4510-50
TRANSDUCER VOLTAGE 24VDC
$235.89000
10 - Immediate
CR Magnetics Inc.CR Magnetics Inc.
1
582-1163-ND
CR4500
Bulk
ActiveTrue RMS AC Voltage Transducer0 ~ 150VAC0 ~ 5VDC2500VDC250ms0.5%24VDCDIN RailScrew Terminal0°C ~ 60°CCE, cURus
CR4510-50
TRANSDUCER VOLTAGE 24VDC
$235.89000
7 - Immediate
CR Magnetics Inc.CR Magnetics Inc.
1
582-1171-ND
CR4500
Bulk
ActiveTrue RMS AC Voltage Transducer0 ~ 50VAC0 ~ 5VDC2500VDC250ms0.5%24VDCDIN RailScrew Terminal0°C ~ 60°CCE, cURus
CR4510-250,CR4510-500
TRANSDUCER VOLTAGE 24VDC
$235.89000
0 - Immediate
CR Magnetics Inc.CR Magnetics Inc.
1
582-1065-ND
CR4500
Box
ActiveTrue RMS AC Voltage Transducer0 ~ 250VAC0 ~ 5VDC2500VDC250ms0.5%24VDCDIN RailScrew Terminal0°C ~ 60°CCE, cURus
IsoBlock I-FG-1C
TRANSDUCER CURRENT 9-28VDC
$264.18000
20 - Immediate
Verivolt LLCVerivolt LLC
1
1780-1007-ND
IsoBlock I-FG
Box
ActiveCurrent Transducer0 ~ 15A±10V1200V (Working)5µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
CR4550-500
TRANSDUCER VOLTAGE 24VDC
$415.94000
5 - Immediate
CR Magnetics Inc.CR Magnetics Inc.
1
582-1177-ND
CR4500
Bulk
ActiveTrue RMS AC Voltage Transducer0 ~ 500VAC0 ~ 5VDC2500VDC250ms0.5%24VDCDIN RailScrew Terminal0°C ~ 60°CCE, cURus
IsoBlock V-1C
TRANSDUCER VOLTAGE 9-28VDC
$416.30000
7 - Immediate
Verivolt LLCVerivolt LLC
1
1780-1055-ND
IsoBlock V
Box
ActiveVoltage Transducer±50V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
2308027
TRANSDUCER CURRENT 24VDC
$427.73000
16 - Immediate
3 - Factory
Phoenix ContactPhoenix Contact
1
277-16677-ND
MCR
Bulk
ActiveCurrent Transducer0 ~ 100A0 ~ 10VDC300VAC (Working), 3500VAC (Test)150ms-24VDCChassis Mount, DIN RailSpring Terminal-40°C ~ 65°CCE, cULus
2308027
TRANSDUCER CURRENT 24VDC
$444.76000
2 - Immediate
Phoenix ContactPhoenix Contact
1
277-14601-ND
MCR
Bulk
ActiveCurrent Transducer0 ~ 100A4 ~ 20mA300VAC (Working), 3500VAC (Test)150ms-24VDCChassis Mount, DIN RailSpring Terminal-40°C ~ 65°CCE, cULus
ISOBLOCK-I-ST-1C-(10A-10V)_View1
TRANSDUCER CURRENT 9-28VDC
$464.33000
4 - Immediate
Verivolt LLCVerivolt LLC
1
1780-1020-ND
IsoBlock I-ST
Box
ActiveCurrent Transducer0 ~ 10A±10V2000V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailScrew Terminal, Spring Terminal-25°C ~ 70°C-
E83-2050
TRANSDUCER CURRENT 10-40VDC
$626.87000
7 - Immediate
Carlo Gavazzi Inc.Carlo Gavazzi Inc.
1
1864-1124-ND
E83
Bag
ActiveCurrent Transducer0 ~ 50A4 ~ 20mA-200ms±2%10 ~ 40VDCDIN RailScrew Terminal-20°C ~ 50°CCE, UL
ENTUBE SE
TRANSDUCER VOLTAGE DIVIDER
$336.24000
2 - Immediate
Verivolt LLCVerivolt LLC
1
1780-1164-ND
Entube SE
Box
ActiveVoltage Transducer±100V±10V--±0.2%-DIN RailSpring Terminal-25°C ~ 70°C-
ENTUBE SE
TRANSDUCER VOLTAGE DIVIDER
$336.24000
2 - Immediate
Verivolt LLCVerivolt LLC
1
1780-1176-ND
Entube SE
Box
ActiveVoltage Transducer±50V±5V--±0.2%-DIN RailSpring Terminal-25°C ~ 70°C-
2813486
TRANSDUCER CURRENT 20-30VDC
$435.23000
2 - Immediate
31 - Factory
Phoenix ContactPhoenix Contact
1
277-5011-ND
MCR
Bulk
ActiveCurrent Transducer0 ~ 100A4 ~ 20mA5000VAC (Test)340ms-20 ~ 30VDCDIN RailScrew Terminal-20°C ~ 60°CCE, cULus
TRANSDUCER CURRENT 9-28VDC
TRANSDUCER CURRENT 9-28VDC
$459.73000
2 - Immediate
Verivolt LLCVerivolt LLC
1
1780-1021-ND
IsoBlock I-ST
Box
ActiveCurrent Transducer±100mV±10V2000V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailScrew Terminal, Spring Terminal-25°C ~ 70°C-
TRANSDUCER CURRENT 9-28VDC
TRANSDUCER CURRENT 9-28VDC
$464.33000
2 - Immediate
Verivolt LLCVerivolt LLC
1
1780-1019-ND
IsoBlock I-ST
Box
ActiveCurrent Transducer0 ~ 20A±10V2000V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailScrew Terminal, Spring Terminal-25°C ~ 70°C-
IsoBlock I-ST-1C (50A 10V)
TRANSDUCER CURRENT 9-28VDC
$528.37000
0 - Immediate
Verivolt LLCVerivolt LLC
1
1780-1016-ND
IsoBlock I-ST
Box
ActiveCurrent Transducer0 ~ 50A±10V2000V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailScrew Terminal, Spring Terminal-25°C ~ 70°C-
2308027
TRANSDUCER CURRENT 24VDC
$553.31000
7 - Immediate
Phoenix ContactPhoenix Contact
1
277-16676-ND
MCR
Bulk
ActiveCurrent Transducer0 ~ 600A4 ~ 20mA300VAC (Working), 3500VAC (Test)150ms-24VDCChassis Mount, DIN RailSpring Terminal-40°C ~ 65°CCE, cULus
Showing
1 - 25
of 414

Monitor - Current/Voltage Transducer


Industrial current or voltage transducers are used to monitor variable or non-sinusoidal sources, trigger peripheral devices in phase-fired control systems, monitor ground current, and other voltage or current monitoring applications. Output types include analog voltage or current, and positive and negative fixed voltages with accuracy from 0.2 to 2%.