SGSSP3-400Q88 Datasheet by Banner Engineering Corporation

BANNER more sensors, more solutions 203637
Important Information
The SGS Safety Grid System instruction manual with installation instructions, application requirements and guidelines, EC Declaration of
Conformity, and technical specifications can be found on the accompanying MiniDVD or downloaded at www.bannerengineering.com
by searching for one of the following part numbers:
Emitter/Receiver: 202015
Emitter/Receiver with Integral Muting: 203065
Active/Passive: 203063
Active/Passive with Integral Muting: 203064
The accompanying MiniDVD contains important warnings and safety instructions that must be observed prior to the installation and
operation of the device. If the MiniDVD cannot be used, download the full Instruction Manual and Checkout Cards (listed in the
manual), including warnings and safety instructions, from www.bannerengineering.com. To order a printed copy or if there are any
questions regarding the application or use of the device, contact Banner Engineering at (763) 544-3164 or at 1-888-3-SENSOR in the
United States.
Table 1: SGS Safety Grid System Emitter/Receiver Models
Model Beams Beam Spacing (mm) Protected Height
(mm) Response Time (ms) (with
no scan code) Response Time (ms) (with
scan code) Operating
Range (m)
SGSSP2-500Q88 2 500 500 12 19
0.5 to 30
SGSSP3-400Q88 3 400 800 13 22
SGSSP4-300Q88 4 300 900 14 25
SGSSP4-400Q88 4 400 1200 14 25
SGSXP2-500Q88 2 500 500 12 19
6 to 60
SGSXP3-400Q88 3 400 800 13 22
SGSXP4-300Q88 4 300 900 14 25
SGSXP4-400Q88 4 400 1200 14 25
Table 2: SGS Safety Grid System Emitter/Receiver with Integral Muting Models
Model Beams Beam Spacing (mm) Protected Height
(mm) Response Time (ms) (with
no scan code) Response Time (ms) (with
scan code) Operating
Range (m)
SGSMP2-500Q128 2 500 500 12 19
0.5 to 30
SGSMP3-400Q128 3 400 800 13 22
SGSMP4-300Q128 4 300 900 14 25
SGSMP4-400Q128 4 400 1200 14 25
Table 3: SGS Safety Grid System Active/Passive Models
Model Type of Unit Equivalent Beams Beam Spacing Protected Height (mm) Response time
(ms) Range (m)
SGSSA2-500Q8
Active Transceiver
2 500 500 11 0.5 to 8
SGSSA3-400Q8 3 380 800 12 0.5 to 8
SGSSA4-300Q8 4 300 900 12 0.5 to 6.5
SGSSA4-400Q8 4 400 1200 12 0.5 to 8
SGSB2-500
Mirror Assembly -
500
- - -
SGSB3-400 380
SGSB4-300 300
SGSB4-400 400
SGS Safety Grid System
Original Document
203637 Rev. A 31 October 2017
203637
more sensors, more solutions
Table 4: SGS Safety Grid System Active/Passive with Integral Muting Models
Model Type of Unit Equivalent Beams Beam Spacing Protected Height (mm) Response time
(ms) Range (m)
SGSMA2-500Q12
Active Transceiver
2 500 500 11 0.5 to 8
SGSMA3-400Q12 3 380 800 12 0.5 to 8
SGSMA4-300Q12 4 300 900 12 0.5 to 6.5
SGSMA4-400Q12 4 400 1200 12 0.5 to 8
SGSB2-500
Mirror Assembly -
500
- - -
SGSB3-400 380
SGSB4-300 300
SGSB4-400 400
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or
replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover
damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY
OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT
DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously
manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the
product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the
product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time.
Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to:
www.bannerengineering.com.
SGS Safety Grid System
© Banner Engineering Corp. All rights reserved