FFC Part Number Guide Datasheet by Parlex USA LLC

View All Related Products | Download PDF Datasheet
SCALE
SIZE FSCM
18377
B
Rev.
-
NA
PS-3705
PROPRIETARY INFORMATION NOTICE
ZIF with Stiffeners on both ends
B
ZIF with Stiffeners both ends Opposite sides
BO
ZIF with Stiffeners one end and Lasered one end
BL
ZIF with Stiffener one end and Blunt cut one end
BT
ZIF with Stiffener on one end only
BN
Cable Length 0.280"±0.030"
Lasered Area
0.112" Ref.
Bussbar
Cables in piece form
Bulk roll with exposed conductors and stiffeners
KW
Bulk roll with exposed conductors and stiffeners on opposite sides
KR
Bulk roll with exposed conductors with stiffeners and double bare area
KL
Bulk roll with exposed conductors and no stiffeners opposite sides
KNO
Bulk roll with exposed conductors and no stiffeners
KN
Double Exposed Area
Cables in bulk form
Bulk roll with exposed conductors and stiffeners every other window
KBN
Bulk roll with exposed conductors and stiffeners every other window opposite sides
KRN
ZIF with no Stiffeners
N
ZIF with no Stiffeners Opposite sides
NO
Cable Blunt cut both ends
TT
ZIF with no Stiffener one end and Blunt cut one end
NT
ZIF with no Stiffener one end and Lasered one end
NL
Cable Length 0.280"±0.030"
Lasered Area
0.112" Ref.
Bussbar
Lasered cable both ends
L
Cable Length 0.280"±0.030"
Lasered Area
0.112" Ref.
Bussbar
Standard
0-3"
3"-6"
6"-12"
12"-18"
18"-24"
24"-36"
±.050" (1.27mm)
±.060" (1.524mm)
±.070" (1.778mm)
±.110" (2.794mm)
±.120" (3.048mm)
±.150" (3.810mm)
Exposed Conductor Length
Stiffener Length
±.030" (.76MM)
±.050" (1.27MM)
Length
Cable
Dimension
Pitch
Margin
±.005" (.127MM)
±.005" (.127MM)
±.005" (.127MM)
Over 36" ±1% OF LENGTH
Pitch Margin UL
Style #
20890
20890
20890
20566
20566
UL Style # Notes
20890 = .008" Min spacing between conductors, Voltage rating = 90 Volts
20566 = .010" Min spacing between conductors, Voltage rating = 90 Volts
2643 = .016" Min spacing between conductors, Voltage rating = 300 Volts
Copper
Thickness Copper
Width
Exposed
Conductor
.014" (.356mm)
.017" (.422mm)
.020" (.495mm)
.023" (.572mm)
.026" (.660mm)
.033" (.845mm)
.034" (.864mm)
.0246" (.625mm)
.025" (.635mm)
.0315" (.800mm)
.0394" (1.00mm)
.0492" (1.25mm)
.050" (1.27mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.170" (4.318mm)
.170" (4.318mm) .003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm) .011" (.280mm)
.016" (.406mm)
.011" (.280mm)
.026" (.660mm)
.0315" (.800mm)
.0315" (.800mm)
Stiffener
Length
.237" (6mm)
.294" (7.5mm)
.237" (6mm)
.237" (6mm)
.237" (6mm)
.237" (6mm)
.294" (7.5mm)
Standard ZIF Cable - Same side exposure
Copper
Width
Current
Rating
.50 AMPS
.50 AMPS
.50 AMPS
1.5 AMPS
.80 AMPS
2.0 AMPS
2.0 AMPS
Cable Width = ( # of conductors +1)*( Pitch )
Mating Thickness = .012" ( .305mm )
Temperature rating = -55°C to 105°C
Dielectric Strength = 2500 Volts/Mil
UL Flame Rating = VW-1
Insulation Resistance = 10 Megaohm min.
Cable Width ±.005" (.127MM)
Span
Span = ( # of conductors -1 )*( Pitch )
.019" (.483mm)
20566 & 2643
20566 & 2643
2643
.069" (1.753mm).100" (2.54mm) .240" (6.096mm) .003" (.076mm) .062" (1.575mm)
.394" (10mm)
3.0 AMPS
Insulation = .002" Polyester with .0015" Flame Retardent Adhesive
Conductors = Copper Tin Plated
.0197" (.500mm)
Exposed Conductor
Cable Length
Stiffener
Cable Width Span
Pitch
Conductor Width
Margin
Mating Thickness
XXXRXX - XXXXXX -
Cable Pitch
# of Conductors
( 1 - 99 ) See below note - ( Dash )
Method
- = Standard
Space ( 1 space between orientation and method )
Orientation of cable ends ( See Sheet 2 )
Cable length in MM ( Up to 4 spaces, No decimal points )
050 = 0.50MM ( 0.0197" )
062 = 0.625MM ( 0.0246" )
100 = 1.00MM ( 0.0394" )
125 = 1.25MM ( 0.0492" )
127 = 1.27MM ( 0.050" )
254 = 2.54MM ( 0.100" )
R = RoHS Compliant
15 Characters maximum
Parlex Standard ZIF Style Cables Part Numbering Configurations
and General Specifications
Standard Part Numbering Configuration
SCALE
SIZE FSCM
18377
B
Rev.
-
NA
PS-3705
Bulk roll with no exposed conductors and no stiffeners with stripe marked over first conductor
KS
KK
Bulk roll with no exposed conductors and no stiffeners
SCALE
SIZE FSCM
18377
B
Rev.
-
NA
PS-3705
Tolerances
Marking - See Note
Notes:
Marking - Minimum marking to be " PARLEX and Date Code". On cables where
spacing does not allow parts will not be marked.
Standard ZIF Cable - Reverse side exposure
Exposed Conductor
Cable Length
Stiffener
Cable Width Span
Pitch
Conductor Width
Margin
Mating Thickness
SCALE
SIZE FSCM
18377
B
Rev.
-
NA
PS-3705
Marking - See Note
SHEET 1 OF 4
SHEET 2 OF 4
SHEET 3 OF 4
SHEET 4 OF 4
Cable end orientations
( For cables with less than 10
Conductors use only 1 number
Ex. 100R8-1252B - )
±.030" (.76MM)
±.050" (1.27MM)
±.005" (.127MM)
±.005" (.127MM)
±.005" (.127MM)
±1% OF LENGTH
±.005" (.127MM)
±.075" (1.905mm)
±.100" (2.54mm)
±.125" (3.175mm)
±.150" (3.810mm)
±.200" (5.08mm)
±.250" (6.35mm)
Pitch Margin UL
Style #
20890
20890
20890
20566
20566
UL Style # Notes
20890 = .008" Min spacing between conductors, Voltage rating = 90 Volts
20566 = .010" Min spacing between conductors, Voltage rating = 90 Volts
2643 = .016" Min spacing between conductors, Voltage rating = 300 Volts
Copper
Thickness Copper
Width
Exposed
Conductor
.014" (.356mm)
.017" (.422mm)
.020" (.495mm)
.023" (.572mm)
.026" (.660mm)
.033" (.845mm)
.034" (.864mm)
.0246" (.625mm)
.025" (.635mm)
.0315" (.800mm)
.0394" (1.00mm)
.0492" (1.25mm)
.050" (1.27mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.170" (4.318mm)
.170" (4.318mm) .003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm) .011" (.280mm)
.016" (.406mm)
.011" (.280mm)
.026" (.660mm)
.0315" (.800mm)
.0315" (.800mm)
Stiffener
Length
.237" (6mm)
.294" (7.5mm)
.237" (6mm)
.237" (6mm)
.237" (6mm)
.237" (6mm)
.294" (7.5mm)
Copper
Width
Current
Rating
.50 AMPS
.50 AMPS
.50 AMPS
1.5 AMPS
.80 AMPS
2.0 AMPS
2.0 AMPS
.019" (.483mm)
20566 & 2643
20566 & 2643
2643
.069" (1.753mm).100" (2.54mm) .240" (6.096mm) .003" (.076mm) .062" (1.575mm)
.394" (10mm)
3.0 AMPS
.0197" (.500mm)
Standard
0-3"
3"-6"
6"-12"
12"-18"
18"-24"
24"-36"
Exposed Conductor Length
Stiffener Length
Length
Cable
Dimension
Pitch
Margin
Over 36"
Cable Width
Span
Tolerances
Cable Width = ( # of conductors +1)*( Pitch )
Mating Thickness = .012" ( .305mm )
Temperature rating = -55°C to 105°C
Dielectric Strength = 2500 Volts/Mil
UL Flame Rating = VW-1
Insulation Resistance = 10 Megaohm min.
Span = ( # of conductors -1 )*( Pitch )
Insulation = .002" Polyester with .0015" Flame Retardent Adhesive
Conductors = Copper Tin Plated
Notes:
Marking - Minimum marking to be " PARLEX and Date Code". On cables where
spacing does not allow parts will not be marked.
This document and the designs, specifications, and engineering
information disclosed herein are the property of Parlex USA LLC
and are not to be disseminated or reproduced without expressed
written consent. This document is loaned in confidence and then
only for consideration of the matter disclosed hereon. In accepting
loan of this document, the recipient agrees to keep it and the matter
disclosed hereon in confidence and not to use or permit their use in
any way detrimental to Parlex USA LLC
A Johnson Electric Company
SCALE
SIZE FSCM
18377
B
Rev.
-
NA
PS-3705
PROPRIETARY INFORMATION NOTICE
ZIF with Stiffeners on both ends
B
ZIF with Stiffeners both ends Opposite sides
BO
ZIF with Stiffeners one end and Lasered one end
BL
ZIF with Stiffener one end and Blunt cut one end
BT
ZIF with Stiffener on one end only
BN
Cable Length 0.280"±0.030"
Lasered Area
0.112" Ref.
Bussbar
Cables in piece form
Bulk roll with exposed conductors and stiffeners
KW
Bulk roll with exposed conductors and stiffeners on opposite sides
KR
Bulk roll with exposed conductors with stiffeners and double bare area
KL
Bulk roll with exposed conductors and no stiffeners opposite sides
KNO
Bulk roll with exposed conductors and no stiffeners
KN
Double Exposed Area
Cables in bulk form
Bulk roll with exposed conductors and stiffeners every other window
KBN
Bulk roll with exposed conductors and stiffeners every other window opposite sides
KRN
ZIF with no Stiffeners
N
ZIF with no Stiffeners Opposite sides
NO
Cable Blunt cut both ends
TT
ZIF with no Stiffener one end and Blunt cut one end
NT
ZIF with no Stiffener one end and Lasered one end
NL
Cable Length 0.280"±0.030"
Lasered Area
0.112" Ref.
Bussbar
Lasered cable both ends
L
Cable Length 0.280"±0.030"
Lasered Area
0.112" Ref.
Bussbar
Standard
0-3"
3"-6"
6"-12"
12"-18"
18"-24"
24"-36"
±.050" (1.27mm)
±.060" (1.524mm)
±.070" (1.778mm)
±.110" (2.794mm)
±.120" (3.048mm)
±.150" (3.810mm)
Exposed Conductor Length
Stiffener Length
±.030" (.76MM)
±.050" (1.27MM)
Length
Cable
Dimension
Pitch
Margin
±.005" (.127MM)
±.005" (.127MM)
±.005" (.127MM)
Over 36" ±1% OF LENGTH
Pitch Margin UL
Style #
20890
20890
20890
20566
20566
UL Style # Notes
20890 = .008" Min spacing between conductors, Voltage rating = 90 Volts
20566 = .010" Min spacing between conductors, Voltage rating = 90 Volts
2643 = .016" Min spacing between conductors, Voltage rating = 300 Volts
Copper
Thickness Copper
Width
Exposed
Conductor
.014" (.356mm)
.017" (.422mm)
.020" (.495mm)
.023" (.572mm)
.026" (.660mm)
.033" (.845mm)
.034" (.864mm)
.0246" (.625mm)
.025" (.635mm)
.0315" (.800mm)
.0394" (1.00mm)
.0492" (1.25mm)
.050" (1.27mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.170" (4.318mm)
.170" (4.318mm) .003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm) .011" (.280mm)
.016" (.406mm)
.011" (.280mm)
.026" (.660mm)
.0315" (.800mm)
.0315" (.800mm)
Stiffener
Length
.237" (6mm)
.294" (7.5mm)
.237" (6mm)
.237" (6mm)
.237" (6mm)
.237" (6mm)
.294" (7.5mm)
Standard ZIF Cable - Same side exposure
Copper
Width
Current
Rating
.50 AMPS
.50 AMPS
.50 AMPS
1.5 AMPS
.80 AMPS
2.0 AMPS
2.0 AMPS
Cable Width = ( # of conductors +1)*( Pitch )
Mating Thickness = .012" ( .305mm )
Temperature rating = -55°C to 105°C
Dielectric Strength = 2500 Volts/Mil
UL Flame Rating = VW-1
Insulation Resistance = 10 Megaohm min.
Cable Width ±.005" (.127MM)
Span
Span = ( # of conductors -1 )*( Pitch )
.019" (.483mm)
20566 & 2643
20566 & 2643
2643
.069" (1.753mm).100" (2.54mm) .240" (6.096mm) .003" (.076mm) .062" (1.575mm)
.394" (10mm)
3.0 AMPS
Insulation = .002" Polyester with .0015" Flame Retardent Adhesive
Conductors = Copper Tin Plated
.0197" (.500mm)
Exposed Conductor
Cable Length
Stiffener
Cable Width Span
Pitch
Conductor Width
Margin
Mating Thickness
XXXRXX - XXXXXX -
Cable Pitch
# of Conductors
( 1 - 99 ) See below note - ( Dash )
Method
- = Standard
Space ( 1 space between orientation and method )
Orientation of cable ends ( See Sheet 2 )
Cable length in MM ( Up to 4 spaces, No decimal points )
050 = 0.50MM ( 0.0197" )
062 = 0.625MM ( 0.0246" )
100 = 1.00MM ( 0.0394" )
125 = 1.25MM ( 0.0492" )
127 = 1.27MM ( 0.050" )
254 = 2.54MM ( 0.100" )
R = RoHS Compliant
15 Characters maximum
Parlex Standard ZIF Style Cables Part Numbering Configurations
and General Specifications
Standard Part Numbering Configuration
SCALE
SIZE FSCM
18377
B
Rev.
-
NA
PS-3705
Bulk roll with no exposed conductors and no stiffeners with stripe marked over first conductor
KS
KK
Bulk roll with no exposed conductors and no stiffeners
SCALE
SIZE FSCM
18377
B
Rev.
-
NA
PS-3705
Tolerances
Marking - See Note
Notes:
Marking - Minimum marking to be " PARLEX and Date Code". On cables where
spacing does not allow parts will not be marked.
Standard ZIF Cable - Reverse side exposure
Exposed Conductor
Cable Length
Stiffener
Cable Width Span
Pitch
Conductor Width
Margin
Mating Thickness
SCALE
SIZE FSCM
18377
B
Rev.
-
NA
PS-3705
Marking - See Note
SHEET 1 OF 4
SHEET 2 OF 4
SHEET 3 OF 4
SHEET 4 OF 4
Cable end orientations
( For cables with less than 10
Conductors use only 1 number
Ex. 100R8-1252B - )
±.030" (.76MM)
±.050" (1.27MM)
±.005" (.127MM)
±.005" (.127MM)
±.005" (.127MM)
±1% OF LENGTH
±.005" (.127MM)
±.075" (1.905mm)
±.100" (2.54mm)
±.125" (3.175mm)
±.150" (3.810mm)
±.200" (5.08mm)
±.250" (6.35mm)
Pitch Margin UL
Style #
20890
20890
20890
20566
20566
UL Style # Notes
20890 = .008" Min spacing between conductors, Voltage rating = 90 Volts
20566 = .010" Min spacing between conductors, Voltage rating = 90 Volts
2643 = .016" Min spacing between conductors, Voltage rating = 300 Volts
Copper
Thickness Copper
Width
Exposed
Conductor
.014" (.356mm)
.017" (.422mm)
.020" (.495mm)
.023" (.572mm)
.026" (.660mm)
.033" (.845mm)
.034" (.864mm)
.0246" (.625mm)
.025" (.635mm)
.0315" (.800mm)
.0394" (1.00mm)
.0492" (1.25mm)
.050" (1.27mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.170" (4.318mm)
.170" (4.318mm) .003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm) .011" (.280mm)
.016" (.406mm)
.011" (.280mm)
.026" (.660mm)
.0315" (.800mm)
.0315" (.800mm)
Stiffener
Length
.237" (6mm)
.294" (7.5mm)
.237" (6mm)
.237" (6mm)
.237" (6mm)
.237" (6mm)
.294" (7.5mm)
Copper
Width
Current
Rating
.50 AMPS
.50 AMPS
.50 AMPS
1.5 AMPS
.80 AMPS
2.0 AMPS
2.0 AMPS
.019" (.483mm)
20566 & 2643
20566 & 2643
2643
.069" (1.753mm).100" (2.54mm) .240" (6.096mm) .003" (.076mm) .062" (1.575mm)
.394" (10mm)
3.0 AMPS
.0197" (.500mm)
Standard
0-3"
3"-6"
6"-12"
12"-18"
18"-24"
24"-36"
Exposed Conductor Length
Stiffener Length
Length
Cable
Dimension
Pitch
Margin
Over 36"
Cable Width
Span
Tolerances
Cable Width = ( # of conductors +1)*( Pitch )
Mating Thickness = .012" ( .305mm )
Temperature rating = -55°C to 105°C
Dielectric Strength = 2500 Volts/Mil
UL Flame Rating = VW-1
Insulation Resistance = 10 Megaohm min.
Span = ( # of conductors -1 )*( Pitch )
Insulation = .002" Polyester with .0015" Flame Retardent Adhesive
Conductors = Copper Tin Plated
Notes:
Marking - Minimum marking to be " PARLEX and Date Code". On cables where
spacing does not allow parts will not be marked.
This document and the designs, specifications, and engineering
information disclosed herein are the property of Parlex USA LLC
and are not to be disseminated or reproduced without expressed
written consent. This document is loaned in confidence and then
only for consideration of the matter disclosed hereon. In accepting
loan of this document, the recipient agrees to keep it and the matter
disclosed hereon in confidence and not to use or permit their use in
any way detrimental to Parlex USA LLC
A Johnson Electric Company
SCALE
SIZE FSCM
18377
B
Rev.
-
NA
PS-3705
PROPRIETARY INFORMATION NOTICE
ZIF with Stiffeners on both ends
B
ZIF with Stiffeners both ends Opposite sides
BO
ZIF with Stiffeners one end and Lasered one end
BL
ZIF with Stiffener one end and Blunt cut one end
BT
ZIF with Stiffener on one end only
BN
Cable Length 0.280"±0.030"
Lasered Area
0.112" Ref.
Bussbar
Cables in piece form
Bulk roll with exposed conductors and stiffeners
KW
Bulk roll with exposed conductors and stiffeners on opposite sides
KR
Bulk roll with exposed conductors with stiffeners and double bare area
KL
Bulk roll with exposed conductors and no stiffeners opposite sides
KNO
Bulk roll with exposed conductors and no stiffeners
KN
Double Exposed Area
Cables in bulk form
Bulk roll with exposed conductors and stiffeners every other window
KBN
Bulk roll with exposed conductors and stiffeners every other window opposite sides
KRN
ZIF with no Stiffeners
N
ZIF with no Stiffeners Opposite sides
NO
Cable Blunt cut both ends
TT
ZIF with no Stiffener one end and Blunt cut one end
NT
ZIF with no Stiffener one end and Lasered one end
NL
Cable Length 0.280"±0.030"
Lasered Area
0.112" Ref.
Bussbar
Lasered cable both ends
L
Cable Length 0.280"±0.030"
Lasered Area
0.112" Ref.
Bussbar
Standard
0-3"
3"-6"
6"-12"
12"-18"
18"-24"
24"-36"
±.050" (1.27mm)
±.060" (1.524mm)
±.070" (1.778mm)
±.110" (2.794mm)
±.120" (3.048mm)
±.150" (3.810mm)
Exposed Conductor Length
Stiffener Length
±.030" (.76MM)
±.050" (1.27MM)
Length
Cable
Dimension
Pitch
Margin
±.005" (.127MM)
±.005" (.127MM)
±.005" (.127MM)
Over 36" ±1% OF LENGTH
Pitch Margin UL
Style #
20890
20890
20890
20566
20566
UL Style # Notes
20890 = .008" Min spacing between conductors, Voltage rating = 90 Volts
20566 = .010" Min spacing between conductors, Voltage rating = 90 Volts
2643 = .016" Min spacing between conductors, Voltage rating = 300 Volts
Copper
Thickness Copper
Width
Exposed
Conductor
.014" (.356mm)
.017" (.422mm)
.020" (.495mm)
.023" (.572mm)
.026" (.660mm)
.033" (.845mm)
.034" (.864mm)
.0246" (.625mm)
.025" (.635mm)
.0315" (.800mm)
.0394" (1.00mm)
.0492" (1.25mm)
.050" (1.27mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.170" (4.318mm)
.170" (4.318mm) .003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm) .011" (.280mm)
.016" (.406mm)
.011" (.280mm)
.026" (.660mm)
.0315" (.800mm)
.0315" (.800mm)
Stiffener
Length
.237" (6mm)
.294" (7.5mm)
.237" (6mm)
.237" (6mm)
.237" (6mm)
.237" (6mm)
.294" (7.5mm)
Standard ZIF Cable - Same side exposure
Copper
Width
Current
Rating
.50 AMPS
.50 AMPS
.50 AMPS
1.5 AMPS
.80 AMPS
2.0 AMPS
2.0 AMPS
Cable Width = ( # of conductors +1)*( Pitch )
Mating Thickness = .012" ( .305mm )
Temperature rating = -55°C to 105°C
Dielectric Strength = 2500 Volts/Mil
UL Flame Rating = VW-1
Insulation Resistance = 10 Megaohm min.
Cable Width ±.005" (.127MM)
Span
Span = ( # of conductors -1 )*( Pitch )
.019" (.483mm)
20566 & 2643
20566 & 2643
2643
.069" (1.753mm).100" (2.54mm) .240" (6.096mm) .003" (.076mm) .062" (1.575mm)
.394" (10mm)
3.0 AMPS
Insulation = .002" Polyester with .0015" Flame Retardent Adhesive
Conductors = Copper Tin Plated
.0197" (.500mm)
Exposed Conductor
Cable Length
Stiffener
Cable Width Span
Pitch
Conductor Width
Margin
Mating Thickness
XXXRXX - XXXXXX -
Cable Pitch
# of Conductors
( 1 - 99 ) See below note - ( Dash )
Method
- = Standard
Space ( 1 space between orientation and method )
Orientation of cable ends ( See Sheet 2 )
Cable length in MM ( Up to 4 spaces, No decimal points )
050 = 0.50MM ( 0.0197" )
062 = 0.625MM ( 0.0246" )
100 = 1.00MM ( 0.0394" )
125 = 1.25MM ( 0.0492" )
127 = 1.27MM ( 0.050" )
254 = 2.54MM ( 0.100" )
R = RoHS Compliant
15 Characters maximum
Parlex Standard ZIF Style Cables Part Numbering Configurations
and General Specifications
Standard Part Numbering Configuration
SCALE
SIZE FSCM
18377
B
Rev.
-
NA
PS-3705
Bulk roll with no exposed conductors and no stiffeners with stripe marked over first conductor
KS
KK
Bulk roll with no exposed conductors and no stiffeners
SCALE
SIZE FSCM
18377
B
Rev.
-
NA
PS-3705
Tolerances
Marking - See Note
Notes:
Marking - Minimum marking to be " PARLEX and Date Code". On cables where
spacing does not allow parts will not be marked.
Standard ZIF Cable - Reverse side exposure
Exposed Conductor
Cable Length
Stiffener
Cable Width Span
Pitch
Conductor Width
Margin
Mating Thickness
SCALE
SIZE FSCM
18377
B
Rev.
-
NA
PS-3705
Marking - See Note
SHEET 1 OF 4
SHEET 2 OF 4
SHEET 3 OF 4
SHEET 4 OF 4
Cable end orientations
( For cables with less than 10
Conductors use only 1 number
Ex. 100R8-1252B - )
±.030" (.76MM)
±.050" (1.27MM)
±.005" (.127MM)
±.005" (.127MM)
±.005" (.127MM)
±1% OF LENGTH
±.005" (.127MM)
±.075" (1.905mm)
±.100" (2.54mm)
±.125" (3.175mm)
±.150" (3.810mm)
±.200" (5.08mm)
±.250" (6.35mm)
Pitch Margin UL
Style #
20890
20890
20890
20566
20566
UL Style # Notes
20890 = .008" Min spacing between conductors, Voltage rating = 90 Volts
20566 = .010" Min spacing between conductors, Voltage rating = 90 Volts
2643 = .016" Min spacing between conductors, Voltage rating = 300 Volts
Copper
Thickness Copper
Width
Exposed
Conductor
.014" (.356mm)
.017" (.422mm)
.020" (.495mm)
.023" (.572mm)
.026" (.660mm)
.033" (.845mm)
.034" (.864mm)
.0246" (.625mm)
.025" (.635mm)
.0315" (.800mm)
.0394" (1.00mm)
.0492" (1.25mm)
.050" (1.27mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.170" (4.318mm)
.170" (4.318mm) .003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm) .011" (.280mm)
.016" (.406mm)
.011" (.280mm)
.026" (.660mm)
.0315" (.800mm)
.0315" (.800mm)
Stiffener
Length
.237" (6mm)
.294" (7.5mm)
.237" (6mm)
.237" (6mm)
.237" (6mm)
.237" (6mm)
.294" (7.5mm)
Copper
Width
Current
Rating
.50 AMPS
.50 AMPS
.50 AMPS
1.5 AMPS
.80 AMPS
2.0 AMPS
2.0 AMPS
.019" (.483mm)
20566 & 2643
20566 & 2643
2643
.069" (1.753mm).100" (2.54mm) .240" (6.096mm) .003" (.076mm) .062" (1.575mm)
.394" (10mm)
3.0 AMPS
.0197" (.500mm)
Standard
0-3"
3"-6"
6"-12"
12"-18"
18"-24"
24"-36"
Exposed Conductor Length
Stiffener Length
Length
Cable
Dimension
Pitch
Margin
Over 36"
Cable Width
Span
Tolerances
Cable Width = ( # of conductors +1)*( Pitch )
Mating Thickness = .012" ( .305mm )
Temperature rating = -55°C to 105°C
Dielectric Strength = 2500 Volts/Mil
UL Flame Rating = VW-1
Insulation Resistance = 10 Megaohm min.
Span = ( # of conductors -1 )*( Pitch )
Insulation = .002" Polyester with .0015" Flame Retardent Adhesive
Conductors = Copper Tin Plated
Notes:
Marking - Minimum marking to be " PARLEX and Date Code". On cables where
spacing does not allow parts will not be marked.
This document and the designs, specifications, and engineering
information disclosed herein are the property of Parlex USA LLC
and are not to be disseminated or reproduced without expressed
written consent. This document is loaned in confidence and then
only for consideration of the matter disclosed hereon. In accepting
loan of this document, the recipient agrees to keep it and the matter
disclosed hereon in confidence and not to use or permit their use in
any way detrimental to Parlex USA LLC
A Johnson Electric Company
SCALE
SIZE FSCM
18377
B
Rev.
-
NA
PS-3705
PROPRIETARY INFORMATION NOTICE
ZIF with Stiffeners on both ends
B
ZIF with Stiffeners both ends Opposite sides
BO
ZIF with Stiffeners one end and Lasered one end
BL
ZIF with Stiffener one end and Blunt cut one end
BT
ZIF with Stiffener on one end only
BN
Cable Length 0.280"±0.030"
Lasered Area
0.112" Ref.
Bussbar
Cables in piece form
Bulk roll with exposed conductors and stiffeners
KW
Bulk roll with exposed conductors and stiffeners on opposite sides
KR
Bulk roll with exposed conductors with stiffeners and double bare area
KL
Bulk roll with exposed conductors and no stiffeners opposite sides
KNO
Bulk roll with exposed conductors and no stiffeners
KN
Double Exposed Area
Cables in bulk form
Bulk roll with exposed conductors and stiffeners every other window
KBN
Bulk roll with exposed conductors and stiffeners every other window opposite sides
KRN
ZIF with no Stiffeners
N
ZIF with no Stiffeners Opposite sides
NO
Cable Blunt cut both ends
TT
ZIF with no Stiffener one end and Blunt cut one end
NT
ZIF with no Stiffener one end and Lasered one end
NL
Cable Length 0.280"±0.030"
Lasered Area
0.112" Ref.
Bussbar
Lasered cable both ends
L
Cable Length 0.280"±0.030"
Lasered Area
0.112" Ref.
Bussbar
Standard
0-3"
3"-6"
6"-12"
12"-18"
18"-24"
24"-36"
±.050" (1.27mm)
±.060" (1.524mm)
±.070" (1.778mm)
±.110" (2.794mm)
±.120" (3.048mm)
±.150" (3.810mm)
Exposed Conductor Length
Stiffener Length
±.030" (.76MM)
±.050" (1.27MM)
Length
Cable
Dimension
Pitch
Margin
±.005" (.127MM)
±.005" (.127MM)
±.005" (.127MM)
Over 36" ±1% OF LENGTH
Pitch Margin UL
Style #
20890
20890
20890
20566
20566
UL Style # Notes
20890 = .008" Min spacing between conductors, Voltage rating = 90 Volts
20566 = .010" Min spacing between conductors, Voltage rating = 90 Volts
2643 = .016" Min spacing between conductors, Voltage rating = 300 Volts
Copper
Thickness Copper
Width
Exposed
Conductor
.014" (.356mm)
.017" (.422mm)
.020" (.495mm)
.023" (.572mm)
.026" (.660mm)
.033" (.845mm)
.034" (.864mm)
.0246" (.625mm)
.025" (.635mm)
.0315" (.800mm)
.0394" (1.00mm)
.0492" (1.25mm)
.050" (1.27mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.170" (4.318mm)
.170" (4.318mm) .003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm) .011" (.280mm)
.016" (.406mm)
.011" (.280mm)
.026" (.660mm)
.0315" (.800mm)
.0315" (.800mm)
Stiffener
Length
.237" (6mm)
.294" (7.5mm)
.237" (6mm)
.237" (6mm)
.237" (6mm)
.237" (6mm)
.294" (7.5mm)
Standard ZIF Cable - Same side exposure
Copper
Width
Current
Rating
.50 AMPS
.50 AMPS
.50 AMPS
1.5 AMPS
.80 AMPS
2.0 AMPS
2.0 AMPS
Cable Width = ( # of conductors +1)*( Pitch )
Mating Thickness = .012" ( .305mm )
Temperature rating = -55°C to 105°C
Dielectric Strength = 2500 Volts/Mil
UL Flame Rating = VW-1
Insulation Resistance = 10 Megaohm min.
Cable Width ±.005" (.127MM)
Span
Span = ( # of conductors -1 )*( Pitch )
.019" (.483mm)
20566 & 2643
20566 & 2643
2643
.069" (1.753mm).100" (2.54mm) .240" (6.096mm) .003" (.076mm) .062" (1.575mm)
.394" (10mm)
3.0 AMPS
Insulation = .002" Polyester with .0015" Flame Retardent Adhesive
Conductors = Copper Tin Plated
.0197" (.500mm)
Exposed Conductor
Cable Length
Stiffener
Cable Width Span
Pitch
Conductor Width
Margin
Mating Thickness
XXXRXX - XXXXXX -
Cable Pitch
# of Conductors
( 1 - 99 ) See below note - ( Dash )
Method
- = Standard
Space ( 1 space between orientation and method )
Orientation of cable ends ( See Sheet 2 )
Cable length in MM ( Up to 4 spaces, No decimal points )
050 = 0.50MM ( 0.0197" )
062 = 0.625MM ( 0.0246" )
100 = 1.00MM ( 0.0394" )
125 = 1.25MM ( 0.0492" )
127 = 1.27MM ( 0.050" )
254 = 2.54MM ( 0.100" )
R = RoHS Compliant
15 Characters maximum
Parlex Standard ZIF Style Cables Part Numbering Configurations
and General Specifications
Standard Part Numbering Configuration
SCALE
SIZE FSCM
18377
B
Rev.
-
NA
PS-3705
Bulk roll with no exposed conductors and no stiffeners with stripe marked over first conductor
KS
KK
Bulk roll with no exposed conductors and no stiffeners
SCALE
SIZE FSCM
18377
B
Rev.
-
NA
PS-3705
Tolerances
Marking - See Note
Notes:
Marking - Minimum marking to be " PARLEX and Date Code". On cables where
spacing does not allow parts will not be marked.
Standard ZIF Cable - Reverse side exposure
Exposed Conductor
Cable Length
Stiffener
Cable Width Span
Pitch
Conductor Width
Margin
Mating Thickness
SCALE
SIZE FSCM
18377
B
Rev.
-
NA
PS-3705
Marking - See Note
SHEET 1 OF 4
SHEET 2 OF 4
SHEET 3 OF 4
SHEET 4 OF 4
Cable end orientations
( For cables with less than 10
Conductors use only 1 number
Ex. 100R8-1252B - )
±.030" (.76MM)
±.050" (1.27MM)
±.005" (.127MM)
±.005" (.127MM)
±.005" (.127MM)
±1% OF LENGTH
±.005" (.127MM)
±.075" (1.905mm)
±.100" (2.54mm)
±.125" (3.175mm)
±.150" (3.810mm)
±.200" (5.08mm)
±.250" (6.35mm)
Pitch Margin UL
Style #
20890
20890
20890
20566
20566
UL Style # Notes
20890 = .008" Min spacing between conductors, Voltage rating = 90 Volts
20566 = .010" Min spacing between conductors, Voltage rating = 90 Volts
2643 = .016" Min spacing between conductors, Voltage rating = 300 Volts
Copper
Thickness Copper
Width
Exposed
Conductor
.014" (.356mm)
.017" (.422mm)
.020" (.495mm)
.023" (.572mm)
.026" (.660mm)
.033" (.845mm)
.034" (.864mm)
.0246" (.625mm)
.025" (.635mm)
.0315" (.800mm)
.0394" (1.00mm)
.0492" (1.25mm)
.050" (1.27mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.140" (3.556mm)
.170" (4.318mm)
.170" (4.318mm) .003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm)
.003" (.076mm) .011" (.280mm)
.016" (.406mm)
.011" (.280mm)
.026" (.660mm)
.0315" (.800mm)
.0315" (.800mm)
Stiffener
Length
.237" (6mm)
.294" (7.5mm)
.237" (6mm)
.237" (6mm)
.237" (6mm)
.237" (6mm)
.294" (7.5mm)
Copper
Width
Current
Rating
.50 AMPS
.50 AMPS
.50 AMPS
1.5 AMPS
.80 AMPS
2.0 AMPS
2.0 AMPS
.019" (.483mm)
20566 & 2643
20566 & 2643
2643
.069" (1.753mm).100" (2.54mm) .240" (6.096mm) .003" (.076mm) .062" (1.575mm)
.394" (10mm)
3.0 AMPS
.0197" (.500mm)
Standard
0-3"
3"-6"
6"-12"
12"-18"
18"-24"
24"-36"
Exposed Conductor Length
Stiffener Length
Length
Cable
Dimension
Pitch
Margin
Over 36"
Cable Width
Span
Tolerances
Cable Width = ( # of conductors +1)*( Pitch )
Mating Thickness = .012" ( .305mm )
Temperature rating = -55°C to 105°C
Dielectric Strength = 2500 Volts/Mil
UL Flame Rating = VW-1
Insulation Resistance = 10 Megaohm min.
Span = ( # of conductors -1 )*( Pitch )
Insulation = .002" Polyester with .0015" Flame Retardent Adhesive
Conductors = Copper Tin Plated
Notes:
Marking - Minimum marking to be " PARLEX and Date Code". On cables where
spacing does not allow parts will not be marked.
This document and the designs, specifications, and engineering
information disclosed herein are the property of Parlex USA LLC
and are not to be disseminated or reproduced without expressed
written consent. This document is loaned in confidence and then
only for consideration of the matter disclosed hereon. In accepting
loan of this document, the recipient agrees to keep it and the matter
disclosed hereon in confidence and not to use or permit their use in
any way detrimental to Parlex USA LLC
A Johnson Electric Company

Products related to this Datasheet

CABLE FFC 22POS 1.00MM 5"
Available Quantity: 7,419
Unit Price: 6.85
CABLE FFC 6POS 1.00MM 5"
Available Quantity: 6,986
Unit Price: 4.11
CABLE FFC 6POS 1.00MM 4"
Available Quantity: 6,274
Unit Price: 4.11
CABLE FFC 12POS 1.00MM 5"
Available Quantity: 5,701
Unit Price: 5.13
CABLE FFC 20POS 1.00MM 4"
Available Quantity: 4,887
Unit Price: 6.85
CABLE FFC 10POS 1.00MM 4"
Available Quantity: 2,399
Unit Price: 4.45
CABLE FFC 24POS 1.00MM 10"
Available Quantity: 2,397
Unit Price: 8.91
CABLE FFC 18POS 1.00MM 7.99"
Available Quantity: 1,980
Unit Price: 7.87
CABLE FFC 20POS 1.00MM 3"
Available Quantity: 1,625
Unit Price: 6.5
CABLE FFC 10POS 1.00MM 10"
Available Quantity: 1,501
Unit Price: 6.5
CABLE FFC 14POS 1.00MM 3"
Available Quantity: 1,482
Unit Price: 5.48
CABLE FFC 20POS 1.00MM 10"
Available Quantity: 0
Unit Price: 9.24
CABLE FFC 30POS 1.00MM 7.99"
Available Quantity: 1,303
Unit Price: 10.26
CABLE FFC 26POS 1.00MM 7.99"
Available Quantity: 1,270
Unit Price: 9.58
CABLE FFC 30POS 1.00MM 4"
Available Quantity: 1,071
Unit Price: 9.24
CABLE FFC 30POS 1.00MM 5"
Available Quantity: 1,047
Unit Price: 8.56
CABLE FFC 26POS 1.00MM 5"
Available Quantity: 1,037
Unit Price: 7.52
CABLE FFC 18POS 1.00MM 5"
Available Quantity: 950
Unit Price: 6.85
CABLE FFC 20POS 1.00MM 7.99"
Available Quantity: 949
Unit Price: 8.21
CABLE FFC 16POS 1.00MM 7.99"
Available Quantity: 908
Unit Price: 7.52
CABLE FFC 16POS 1.00MM 3"
Available Quantity: 844
Unit Price: 5.82
CABLE FFC 24POS 1.00MM 7.99"
Available Quantity: 790
Unit Price: 8.21
CABLE FFC 16POS 1.00MM 4"
Available Quantity: 741
Unit Price: 6.17
CABLE FFC 22POS 1.00MM 4"
Available Quantity: 715
Unit Price: 6.5
CABLE FFC 33POS 0.50MM 13"
Available Quantity: 595
Unit Price: 24.02
CABLE FFC 10POS 1.00MM 3"
Available Quantity: 508
Unit Price: 4.11
CABLE FFC 24POS 1.00MM 4"
Available Quantity: 503
Unit Price: 7.51
CABLE FFC 6POS 1.00MM 10"
Available Quantity: 446
Unit Price: 5.82
CABLE FFC 10POS 1.00MM 5"
Available Quantity: 375
Unit Price: 5.48
CABLE FFC 16POS 1.00MM 5"
Available Quantity: 373
Unit Price: 6.5
CABLE FFC 10POS 1.00MM 7.99"
Available Quantity: 317
Unit Price: 6.5
CABLE FFC 16POS 1.00MM 10"
Available Quantity: 310
Unit Price: 8.21
CABLE FFC 24POS 1.00MM 5"
Available Quantity: 296
Unit Price: 7.19
CABLE FFC 24POS 1.00MM 3"
Available Quantity: 286
Unit Price: 6.5
CABLE FFC 26POS 1.00MM 4"
Available Quantity: 258
Unit Price: 7.87
CABLE FFC 6POS 1.00MM 7.99"
Available Quantity: 258
Unit Price: 5.13
CABLE FFC 18POS 1.00MM 4"
Available Quantity: 251
Unit Price: 6.5
CABLE FFC 22POS 1.00MM 3"
Available Quantity: 243
Unit Price: 6.17
CABLE FFC 26POS 1.00MM 3"
Available Quantity: 230
Unit Price: 7.52
CABLE FFC 30POS 1.00MM 3"
Available Quantity: 208
Unit Price: 7.52
CABLE FFC 14POS 1.00MM 7.99"
Available Quantity: 198
Unit Price: 7.19
CABLE FFC 14POS 1.00MM 10"
Available Quantity: 179
Unit Price: 7.19
CABLE FFC 30POS 1.00MM 10"
Available Quantity: 123
Unit Price: 9.93
CABLE FFC 8POS 1.00MM 4"
Available Quantity: 78
Unit Price: 4.11
CABLE FFC 8POS 1.00MM 7.99"
Available Quantity: 39
Unit Price: 6.17
CABLE FFC 17POS 1.00MM 4"
Available Quantity: 7
Unit Price: 6.17
CABLE FFC 17POS 1.00MM 5"
Available Quantity: 5
Unit Price: 6.5
CABLE FFC 4POS 1.00MM 5.98"
Available Quantity: 2
Unit Price: 4.45
CABLE FFC 12POS 1.00MM 3"
Available Quantity: 0
Unit Price: 5.13
CABLE FFC 18POS 1.00MM 3"
Available Quantity: 0
Unit Price: 2.73804
CABLE FFC 28POS 1.00MM 3"
Available Quantity: 0
Unit Price: 3.4986
CABLE FFC 12POS 1.00MM 4"
Available Quantity: 0
Unit Price: 5.48
CABLE FFC 14POS 1.00MM 4"
Available Quantity: 0
Unit Price: 5.82
CABLE FFC 28POS 1.00MM 4"
Available Quantity: 0
Unit Price: 3.65072
CABLE FFC 8POS 1.00MM 5"
Available Quantity: 0
Unit Price: 5.13
CABLE FFC 14POS 1.00MM 5"
Available Quantity: 0
Unit Price: 6.17
CABLE FFC 20POS 1.00MM 5"
Available Quantity: 0
Unit Price: 7.19
CABLE FFC 28POS 1.00MM 5"
Available Quantity: 0
Unit Price: 3.80282
CABLE FFC 12POS 1.00MM 7.99"
Available Quantity: 0
Unit Price: 6.85
CABLE FFC 22POS 1.00MM 7.99"
Available Quantity: 0
Unit Price: 3.80282
CABLE FFC 28POS 1.00MM 7.99"
Available Quantity: 0
Unit Price: 4.41128
CABLE FFC 8POS 1.00MM 10"
Available Quantity: 0
Unit Price: 6.85
CABLE FFC 12POS 1.00MM 10"
Available Quantity: 0
Unit Price: 7.52
CABLE FFC 18POS 1.00MM 10"
Available Quantity: 0
Unit Price: 8.56
CABLE FFC 22POS 1.00MM 10"
Available Quantity: 0
Unit Price: 4.25916
CABLE FFC 26POS 1.00MM 10"
Available Quantity: 0
Unit Price: 4.5634
CABLE FFC 28POS 1.00MM 10"
Available Quantity: 0
Unit Price: 4.7155
CABLE FFC 10POS 0.50MM 2"
Available Quantity: 0
Unit Price: 6.5
CABLE FFC 14POS 1.00MM 25"
Available Quantity: 0
Unit Price: 0
CABLE FFC 17POS 1.00MM 3"
Available Quantity: 0
Unit Price: 2.58592
CABLE FFC 17POS 1.00MM 5.98"
Available Quantity: 0
Unit Price: 3.04226
CABLE FFC 17POS 1.00MM 7.99"
Available Quantity: 0
Unit Price: 3.34648
CABLE FFC 40POS 0.50MM 0.67"
Available Quantity: 0
Unit Price: 0
CABLE FFC 9POS 1.00MM 5.98"
Available Quantity: 0
Unit Price: 0
CABLE FFC 40POS 0.50MM 7.01"
Available Quantity: 0
Unit Price: 0
CABLE FFC 11POS 1.00MM 10"
Available Quantity: 0
Unit Price: 0
CABLE FFC 11POS 1.00MM 12"
Available Quantity: 0
Unit Price: 0
CABLE FFC 13POS 1.00MM 3"
Available Quantity: 0
Unit Price: 0
CABLE FFC 11POS 1.00MM 5"
Available Quantity: 0
Unit Price: 0
CABLE FFC 11POS 1.00MM 7.99"
Available Quantity: 0
Unit Price: 0
CABLE FFC 13POS 1.00MM 4"
Available Quantity: 0
Unit Price: 0
CABLE FFC 11POS 1.00MM 5.98"
Available Quantity: 0
Unit Price: 0
CABLE FFC 13POS 1.00MM 2"
Available Quantity: 0
Unit Price: 0
CABLE FFC 11POS 1.00MM 18"
Available Quantity: 0
Unit Price: 0
CABLE FFC 13POS 1.00MM 5"
Available Quantity: 0
Unit Price: 0
CABLE FFC 23POS 1.00MM 12"
Available Quantity: 0
Unit Price: 0
CABLE FFC 25POS 1.00MM 7.99"
Available Quantity: 0
Unit Price: 0
CABLE FFC 25POS 1.00MM 12"
Available Quantity: 0
Unit Price: 0
CABLE FFC 25POS 1.00MM 3"
Available Quantity: 0
Unit Price: 0
CABLE FFC 25POS 1.00MM 5"
Available Quantity: 0
Unit Price: 0
CABLE FFC 25POS 1.00MM 5.98"
Available Quantity: 0
Unit Price: 0
CABLE FFC 23POS 1.00MM 18"
Available Quantity: 0
Unit Price: 0
CABLE FFC 25POS 1.00MM 10"
Available Quantity: 0
Unit Price: 0
CABLE FFC 25POS 1.00MM 4"
Available Quantity: 0
Unit Price: 0
CABLE FFC 25POS 1.00MM 2"
Available Quantity: 0
Unit Price: 0
CABLE FFC 13POS 1.00MM 7.99"