1172C Datasheet

Alpha Wire

View All Related Products | Download PDF Datasheet

Datasheet

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 291
Communication, Control,
and Industrial Cable
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Get control of demanding applications
T
he broad range of
communication and control
cables from Alpha Wire
means you can find the right cable
for your application. Our cables
meet special needs, such as low-
capacitance cables for extended
transmission of digital signals,
such as the extra flexibility of
rubber insulation and jackets, or
excellent shielding for electrically
noisy environments.
We combine a wide range of
insulation materials, shielding
variations, conductor counts and
gauges, as well as other options
to create cables suited to any
application. From traditional
RS-232 connections to high-speed
telemetry and data recording to
high-fidelity microphone systems,
our experience in materials and
expertise in manufacturing means
cable built to perform electrically,
mechanically, and environmentally.
Our communication and
control line includes six
main categories:
Solar cable:
a full range of solar cables for
power and control.
Industrial automation cable:
cable for common automation
protocols such as ControlNet,
DeviceNet, and PROFIBUS.
Flexible motor supply cable:
four-conductor double-shielded
cable suited for light-duty flexing.
Communication and control:
round multiconductor and
multipair cable in configurations
suited to nearly any application.
Low-smoke, zero-halogen cable:
minimizes the effects from
smoke and harmful corrosive
gases in the event of combustion.
Flat cable:
planar multiconductor cable
used primarily inside cabinets
or equipment.
292
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 293
Solar Cable
F
rom residential rooftops
to solar farms harvesting
energy, our solar cables and
photovoltaic wire are designed
for the harsh environments of solar
energy applications—the hot and
cold of climate extremes, ozone
and UV radiation, moisture, oil,
and direct burial. Our specially
formulated PVC jackets provide
years of reliable service by
withstanding the potential
environments without failing
or degrading.
A full range for power and control
No matter what your need in
connecting solar power to the grid,
we have wire and cable in a range
of gauges and conductor counts
to satisfy it.
Our cables meet regulatory
and industry requirements for
photovoltaic applications.
Applications
Panel monitoring and control
Panel to junction box
Panel to collector
Collector to inverter
Grounding
Motor supply
Photovoltaic Wire
For single-conductor needs,
see page 417 for our line of
photovoltaic wires.
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
294
Cable > Communication, Control and Industrial > Multiconductor > Braid Shield > 1000 V
Solar Cable
1000 V Braid Shield, Multiconductor, PVC/Nylon, PVC
UL TC-ER
UL WTTC (1000 V)
UL MTW
CSA AWM I/II A/B FT1
Operating Temperature
-40°C to +90°C (static)
-30°C to +90°C (dynamic)
+105°C (CSA)
Conductor Color Coding
Chart F (page 532)
Materials
Stranded bare copper
conductors
PVC/nylon insulation
Clear polyester wrap
Tinned copper braid shield,
85% coverage
Green PVC jacket
Features
UL Sunlight Resistant
UL Oil Res. I
UL Direct Burial
Suitable for use in Class I,
Division 2 locations per Article
501 of the National Electric Code
Availability
Bulk, cut to length
FIT® Tubing Recommendations
FIT-260: Cross-linked polyolefin
for ground identification
FIT-300: Dual-wall polyolefin
with meltable inner wall
FIT-750: Bonding adhesive-lined
cross-linked polyolefin
18 AWG (0.96 mm2)
Stranding: 19/30 (19 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.12 mm) nylon
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
SPM1803CY 3 0.329 8.36 0.050 1.27
SPM1804CY 4 0.354 8.99 0.050 1.27
SPM1805CY 5 0.381 9.68 0.050 1.27
SPM1807CY 7 0.409 10.39 0.050 1.27
SPM1809CY 9 0.466 11.84 0.050 1.27
16 AWG (1.32 mm2)
Stranding: 26/30 (26 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.12 mm) nylon
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
SPM1603CY 3 0.351 8.92 0.050 1.27
SPM1604CY 4 0.378 9.60 0.050 1.27
SPM1605CY 5 0.408 10.36 0.050 1.27
SPM1607CY 7 0.439 11.15 0.050 1.27
SPM1609CY 9 0.509 12.93 0.050 1.27
14 AWG (2.08 mm2)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.12 mm) nylon
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
SPM1403CY 3 0.381 9.68 0.050 1.27
SPM1404CY 4 0.412 10.46 0.050 1.27
SPM1405CY 5 0.446 11.33 0.050 1.27
SPM1407CY 7 0.481 12.22 0.050 1.27
SPM1409CY 9 0.590 14.99 0.065 1.65
12 AWG (3.29 mm2)
Stranding: 65/30 (65 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.12 mm) nylon
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
SPM1203CY 3 0.422 10.72 0.050 1.27
SPM1204CY 4 0.458 11.63 0.050 1.27
SPM1205CY 5 0.497 12.62 0.050 1.27
SPM1207CY 7 0.574 14.58 0.065 1.65
SPM1209CY 9 0.659 16.74 0.065 1.65
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 295
Cable > Communication, Control and Industrial > Multiconductor > Unshielded > 1000 V
Solar Cable
1000 V Unshielded, Multiconductor, PVC/Nylon, PVC
UL TC-ER
UL WTTC (1000 V)
UL MTW
CSA AWM I/II A/B FT1
Operating Temperature
-40°C to +90°C (static)
-30°C to +90°C (dynamic)
+105°C (CSA)
Conductor Color Coding
Chart F (page 532)
Materials
Stranded bare copper
conductors
PVC/nylon insulation
Clear polyester wrap
Green PVC jacket
Features
UL Sunlight Resistant
UL Oil Res. I
UL Direct Burial
Suitable for use in Class I,
Division 2 locations per Article
501 of the National Electric Code
Availability
Bulk, cut to length
FIT® Tubing Recommendations
FIT-260: Cross-linked polyolefin
for ground identification
FIT-300: Dual-wall polyolefin
with meltable inner wall
FIT-750: Bonding adhesive-lined
cross-linked polyolefin
18 AWG (0.96 mm2)
Stranding: 19/30 (19 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.12 mm) nylon
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
SPM1803 3 0.301 7.65 0.050 1.27
SPM1804 4 0.326 8.28 0.050 1.27
SPM1805 5 0.353 8.97 0.050 1.27
SPM1807 7 0.381 9.68 0.050 1.27
SPM1809 9 0.438 11.13 0.050 1.27
12 AWG (3.29 mm2)
Stranding: 65/30 (65 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.12 mm) nylon
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
SPM1203 3 0.394 10.01 0.050 1.27
SPM1204 4 0.430 10.92 0.050 1.27
SPM1205 5 0.469 11.91 0.050 1.27
SPM1207 7 0.510 12.95 0.050 1.27
SPM1209 9 0.625 15.88 0.065 1.65
16 AWG (1.32 mm2)
Stranding: 26/30 (26 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.12 mm) nylon
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
SPM1603 3 0.323 8.20 0.050 1.27
SPM1604 4 0.350 8.89 0.050 1.27
SPM1605 5 0.380 9.65 0.050 1.27
SPM1607 7 0.411 10.44 0.050 1.27
SPM1609 9 0.475 12.07 0.050 1.27
14 AWG (2.08 mm2)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.12 mm) nylon
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
SPM1403 3 0.353 8.97 0.050 1.27
SPM1404 4 0.384 9.75 0.050 1.27
SPM1405 5 0.418 10.62 0.050 1.27
SPM1407 7 0.453 11.51 0.050 1.27
SPM1409 9 0.556 14.12 0.065 1.65
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
296
Industrial Automation Cable
Seamless communication for robust industrial environments
W
hether you are designing
a device for error
proofing to increase
quality or motion sensing
to improve safety, trust Alpha
Wire for all your Industrial
Automation needs.
As industrial automation systems
continue to increase in complexity,
we understand the challenges that
engineers and manufacturers face
in designing and interconnecting
system components from sensors
to top-level controllers. Our
range of industrial automation
cables combines the industry-
leading quality and exceptional
reliability you expect with Alpha
Wire with the performance to
meet the rigorous requirements
of the major automation
communication architectures.
ControlNet™
Low-loss RG-6/U coax designed
to meet the high-speed, time-
critical requirements of modern
ControlNet factory-floor
automation systems.
RS-485
Bringing proven data
transmission protocol to the
factory floor, rugged RS-485
cables reduce electrical noise
sensitivity to keep reliability and
performance at world-class levels.
DeviceNet™
Meeting ODVA thick and thin
specifications, the cables comply
with Allen-Bradley 1485 CPI-A and
1485 CPI-C, and support high data
rates (500 kb/s at 100 m and 125
kb/s at 500 m).
Fieldbus and PROFIBUS®
A complete family meets
ruggedness, performance, and
quality requirements of almost
any fieldbus and PROFIBUS
application environment.
Industrial Twinax
A robust physical media for the
transmission of PLC/DCS signals
in real-time, high-throughput
applications, including Allen-
Bradley Data Highway networks.
The cables may be installed in the
same tray or conduit as 600-volt
power cable.
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 297
Cable > Communication, Control and Industrial > Double Braid and Foil Shielded > 300 V
ControlNet
300 V, RG-6/U Coaxial Cable, Double Braid and Foil Shielded
UL CL2R
UL CMR
CSA CMG FT4
Operating Temperature
-30°C to +75°C
Materials
Solid bare Copperweld
conductor
Foam polyethylene insulation
Shielding: double braid and foil
Foil +60% aluminum braid +
foil +40% aluminum braid
Black PVC jacket
Features
UL Sunlight Resistant
75-ohm nominal impedance
82% velocity of propagation
16.2 pF/ft (53.1 pF/m) nominal
capacitance
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
FIT® Tubing Recommendations
FIT-221: General-purpose,
cross-linked polyolefin
FIT-321: Medium-wall, adhesive-
lined, cross-linked polyolefin
Part No. Nominal Diameter Center Conductor Nominal Impedance
(ohms)
Inch mm AWG mm2
6458 0.298 7.57 18 0.82 75
Nominal Attenuation
Frequency (MHz) Attenuation, Nom.
dB/100 ft dB/100 m
1 0.35 1.1
2 0.38 1.2
5 0.45 1.5
10 0.59 1.9
20 0.86 2.8
50 1.37 4.5
100 1.97 6.5
200 2.82 9.3
300 3.48 11.4
400 4.04 13.3
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
298
Cable > Communication, Control and Industrial > Foil Shielded, Individual Pairs > Braid Shield Overall > 300 V
DeviceNet
300 V Power and Data, Class 2, ODVA Thick and Thin Trunks
UL CMG
UL PLTC-ER (Thick)
UL CL2 (Thin)
CSA CMG FT4
CSA AWM I/II A/B FT4
Operating Temperature
-20°C to +75°C (static)
0°C to +80°C (dynamic)
Conductor Color Coding
Black-red power
Blue-white data
Materials
Tinned copper conductors
Each pair individually foil
shielded
PVC insulation (power pair)
Foam HDPE insulation
(data pair)
65% tinned copper braid overall
Slate PVC jacket
Features
Oil resistant
UL Sunlight Resistant
120-ohm nominal impedance
(data pair)
Compliant with Allen-Bradley
part numbers 1485 CPI-A and
1485 CPI-C
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Part No. Type Pairs Nominal Diameter
Inch mm
6451 Thick
1 Power: 15 AWG (1.75 mm2), 19/0.0135
(19 x 0.35 mm) stranding
1 Data: 18 AWG (0.96 mm2), 19/30
(19 x 0.25 mm) stranding
0.480 12.19
6452 Thin
1 Power: 22 AWG (0.38 mm2), 19/34
(19 x 0.16 mm) stranding
1 Data: 24 AWG (0.24 mm2), 19/36
(19 x 0.13 mm) stranding
0.280 7.11
FIT® Tubing Recommendations
FIT-221: General-purpose,
cross-linked polyolefin
FIT-321: Medium-wall, adhesive-
lined, cross-linked polyolefin
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 299
UL PLTC-ER
UL CM
UL ITC
CSA CM
Operating Temperature
-30°C to +105°C
Conductor Color Coding
Blue-orange
Materials
Tinned copper conductors
Polyolefin insulation
Foil shield
Orange PVC jacket
Features
UL Sunlight Resistant
100-ohm nominal impedance
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
FIT® Tubing Recommendations
FIT-221: General-purpose,
cross-linked polyolefin
FIT-321: Medium-wall, adhesive-
lined, cross-linked polyolefin
Cable > Communication, Control and Industrial > Single-Pair > Foil Shielded > 300 V
Fieldbus
300 V Single-Pair Cable, Fieldbus Types A and B
Part No. Fieldbus
Type Pairs Conductor Stranding Nominal Diameter
AWG mm2AWG mm Inch mm
6459 A 1 18 0.90 7/26 7 x 0.40 0.253 6.43
6460 B 1 22 0.33 7/0.0096 7 x 0.24 0.196 4.97
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
300
Cable > Communication, Control and Industrial > Single-Pair > Foil Shielded > 300 V
High-Speed Fieldbus
300 V Single-Pair Cable
UL PLTC
UL CM
CSA CM
Operating Temperature
-40°C to +75°C
Conductor Color Coding
Blue-orange
Materials
Tinned copper conductors
Foam high-density
polyethylene insulation
Foil shield
Orange PVC jacket
Features
UL Sunlight Resistant
150-ohm nominal impedance
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
FIT® Tubing Recommendations
FIT-221: General-purpose,
cross-linked polyolefin
FIT-321: Medium-wall, adhesive-
lined, cross-linked polyolefin
Part No. Pairs Conductor Stranding Nominal Diameter
AWG mm2AWG mm Inch mm
6461 1 22 0.35 7/30 7 x 0.25 0.351 8.92
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 301
Cable > Communication, Control and Industrial > Single-Pair > Foil + Braid Shield > 300 V
PROFIBUS-DP
300 V Single-Pair Cable
UL AWM 20201 (6462 only)
UL PLTC
UL CMG
CSA CMG FT4
Operating Temperature
-30°C to +75°C (PLTC, CMG)
-30°C to +60°C (AWM)
Conductor Color Coding
Red-green
Materials
Tinned solid or stranded copper
conductors
Foam high-density polyethylene
insulation
Foil + 65% tinned copper
braid shield
Purple PVC jacket
Features
UL Sunlight Resistant
150-ohm nominal impedance
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
FIT® Tubing Recommendations
FIT-221: General-purpose,
cross-linked polyolefin
FIT-321: Medium-wall, adhesive-
lined, cross-linked polyolefin
Part No. Pairs Conductor Stranding Nominal Diameter
AWG mm2AWG mm Inch mm
6462 1 22 0.32 Solid 0.315 8.00
6463 1 22 0.35 7/30 7 x 0.25 0.315 8.00
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
302
Cable > Communication, Control and Industrial > Multipair > Foil + Braid > 300 V
RS-485 Cable
300 V Foil + Braid, Multipair
UL CM, CMG
UL TC, PLTC
CSA CM, CMG FT1
Operating Temperature
-20°C to +60°C
Conductor Color Coding
Chart M (page 530), except
6454
Materials
Tinned copper conductors
Foam high-density polyethylene
insulation
Foil + 65% tinned copper
braid shield
Black PVC jacket
Features
UL Sunlight Resistant
120-ohm nominal impedance
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
FIT® Tubing Recommendations
FIT-221: General-purpose,
cross-linked polyolefin
FIT-321: Medium-wall, adhesive-
lined, cross-linked polyolefin
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Part No. Pairs Nominal Diameter Insulation Thickness Jacket Thickness
Inch mm Inch mm Inch mm
6453 1 0.284 7.21 0.028 0.71 0.042 1.07
6454* 1.5 0.300 7.62 0.032 0.81 0.042 1.07
6455 2 0.408 10.36 0.024 0.61 0.053 1.35
6456 3 0.414 10.52 0.022 0.56 0.053 1.35
6457 4 0.448 11.38 0.022 0.56 0.053 1.35
*Conductor color coding: white/orange-orange/white pair, white-blue single conductor.
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 303
Cable > Communication, Control and Industrial > Single Pair > Foil + Braid Shield > 600 V
Industrial Twinax
600 V Foil + Braid Shield, Single Pair
UL TC, PLTC, ITC
UL CMG
CSA CMG FT4
Operating Temperature
-40°C to +75°C
Conductor Color Coding
Blue-white
Materials
Tinned stranded copper
conductors
Flame-resistant polypropylene
insulation
Foil + 55% tinned copper
braid shield
Blue PVC jacket
Features
UL Sunlight Resistant
78-ohm nominal impedance
Meets the requirements of Allen-
Bradley Data Highway Networks
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
FIT® Tubing Recommendations
FIT-221: General-purpose,
cross-linked polyolefin
FIT-321: Medium-wall, adhesive-
lined, cross-linked polyolefin
Part No. Pairs Conductor Stranding Nominal Diameter
AWG mm2AWG mm Inch mm
6450 1 18 0.90 7/26 7 x 0.40 0.324 8.23
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
304
Cable > Communication, Control and Industrial > Motor Supply > Shielded > 600 V
Flexible Motor Supply Cable
Light Duty Flexing
600 V Foil/Braid, Four Conductor
UL TC-ER
UL MTW
UL WTTC
CSA AWM l/ll A/B FT4
CE
Operating Temperature
-5°C to +90°C (flexing)
-20°C to +90°C (stationary)
Conductor Color Coding
One yellow/green and three
numbered black
Materials
Finely stranded bare copper
conductors
PVC/nylon insulation
Foil + braid shield
Aluminum/polyester/aluminum
foil shield, with 25% overlap and
four tinned copper drain wires
Tinned copper braid with
70% coverage
Black PVC jacket
16 to 6 AWG (1.49 to 5.33 mm2)
Part No. Conductors Wire Size Stranding Nominal Diameter Jacket Thickness Insulation Thickness
AWG mm2AWG mm Inch mm Inch mm Inch mm
5660 4 16 1.32 26/30 26 x 0.25 0.381 9.67 0.050 1.27 0.016 0.40
5661 4 14 2.08 41/30 41 x 0.25 0.418 10.61 0.050 1.27 0.016 0.40
5662 4 12 3.30 65/30 65 x 0.25 0.464 11.78 0.050 1.27 0.016 0.40
5663 4 10 5.32 105/30 105 x 0.25 0.579 14.70 0.063 1.60 0.022 0.55
5664 4 8 8.52 168/30 168 x 0.25 0.760 19.30 0.063 1.60 0.032 0.81
5665 4 6 13.49 266/30 266 x 0.25 0.901 22.88 0.083 2.10 0.032 0.81
Voltage
600 V (UL TC-ER, MTW)
1000 V (UL WTTC)
Availability
Bulk, cut to length
FIT® Tubing Recommendations
FIT-321: Medium-wall, adhesive-
lined, cross-linked polyolefin
FIT-600: Highly flexible,
cross-linked elastomer
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 305
A Full Range of Communication
and Control
O
ur line-up of standard
communication and
control cables gives you
maximum choice and fewer tradeoffs.
By offering you a comprehensive
collection of insulation/jacketing
materials, shielding options, and
conductor counts, you can easily
select the cable that meets your
most demanding needs. We have
cables that go beyond the ordinary
to satisfy rigorous requirements
of EMI performance, transmission
distances, flexibility, and
temperature extremes.
Communication and control
typical applications:
Audio systems: speakers,
microphones, intercoms
Broadcast and studio
Data transmission: RS-232,
422, 485
CAD/CAM
Computer peripherals
Business machines
Security systems: alarms,
cameras, sensors
Control systems
Instrumentation systems
Point-of-sale systems
Banking systems
Communication and control
key features:
1 – 50 conductors, 1 – 50 pairs
Wide range of insulation/
jacket materials:
PVC
Irradiated PVC
Plenum-rated PVC
Semirigid PVC
Rubber
Polyethylene
Polypropylene
Foam PP and PE
PTFE/FEP
LSZH
Low-capacitance cables for
improved transmission distances
and signal integrity
Flexible shielding options:
Unshielded
Overall foil shield
Overall foil/braid
Individual foil-shielded pairs
Individual foil-shielded pairs
with overall foil/braid
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
306
Cable > Communication, Control and Industrial > Low-Smoke, Zero-Halogen (LSZH)
Communication and Control Cable
300 V Unshielded, Multiconductor, LSZH
Alpha Wire’s LSZH communica-
tion and control cable combines
LSZH-rated insulation and jackets
with the rugged performance
you expect from Alpha. The
specially formulated LSZH material
minimizes the effects from smoke
and harmful corrosive gases in the
event of combustion. Low smoke
means easier visibility in exiting
the area and reduced danger of
smoke inhalation, while low toxicity
means no harm to people from
halogenated gases.
LSZH Unshielded Multiconductor
Conductor Color Coding: Chart D
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1172L 2 0.161 4.09 0.028 0.71
1173L 3 0.169 4.29 0.028 0.71
1174L 4 0.189 4.80 0.028 0.71
1175L 5 0.201 5.11 0.028 0.71
1176L 6 0.209 5.31 0.030 0.76
1177L 7 0.209 5.31 0.030 0.76
1178L 8 0.220 5.59 0.030 0.76
1179L 9 0.249 6.32 0.032 0.81
1180L 10 0.260 6.60 0.035 0.88
20 AWG (0.56 mm2)
Stranding: 7/28 (0.32 mm)
Insulation thickness: 0.016 (0.40 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1895L 2 0.181 4.60 0.018 0.45
1896L 3 0.189 4.80 0.020 0.50
1896/4L 4 0.209 5.31 0.020 0.50
1896/5L 5 0.232 5.89 0.020 0.50
1896/6L 6 0.276 7.01 0.020 0.50
UL CM VW-1
CSA CMG FT4
Operating Temperature
-20°C to +75°C
Materials
Stranded tinned copper
conductors
LSZH insulation
Slate LSZH jacket
LSZH Properties
LSZH Flammability:
Passes IEC 60332-1
LSZH Acid Gas Generation:
Passes IEC 60754-1 and 60754-2
LSZH Smoke Emission:
Passes IEC 61034-2
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 307
LSZH Overall Foil Shielded Multipair
Conductor Color Coding: Chart A
24 AWG (0.22 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Pairs Nominal Diameter Jacket Thickness
Inch mm Inch mm
5471L 1 0.161 4.09 0.028 0.71
5472L 2 0.209 5.31 0.028 0.71
5473L 3 0.228 5.79 0.028 0.71
5474L 4 0.240 6.10 0.028 0.71
5475L 5 0.272 6.91 0.030 0.76
5476L 6 0.299 7.59 0.030 0.76
5477L 7 0.299 7.59 0.030 0.76
5478L 8 0.319 8.10 0.032 0.81
5479L 9 0.339 8.61 0.032 0.81
5480L 10 0.378 9.60 0.032 0.81
LSZH Individually Foil-Shielded Pair
Conductor Color Coding: Chart A
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Pairs Nominal Diameter Jacket Thickness
Inch mm Inch mm
2466L*† 2 0.161 4.09 0.014 0.35
6010L 3 0.299 7.59 0.047 1.19
2463L*†† 4 0.242 6.15 0.020 0.50
6012L 6 0.386 9.80 0.040 1.01
6014L 9 0.441 11.20 0.040 1.01
6017L 12 0.492 12.50 0.040 1.01
Alpha Wire’s LSZH communica-
tion and control cable combines
LSZH-rated insulation and jackets
with the rugged performance
you expect from Alpha. The
specially formulated LSZH material
minimizes the effects from smoke
and harmful corrosive gases in the
event of combustion. Low smoke
means easier visibility in exiting
the area and reduced danger of
smoke inhalation, while low toxicity
means no harm to people from
halogenated gases.
UL CM VW-1
CSA CMG FT4
Operating Temperature
-20°C to +75°C
Materials
Stranded tinned copper
conductors
LSZH insulation (Polypropylene
insulation for individually foil
shielded pairs)
Aluminum/polyester shielding,
with 25% overlap min.
Foil facing inward
Tinned copper drain wire sized
the same as the conductors
Slate LSZH jacket
LSZH Properties
LSZH Flammability:
Passes IEC 60332-1
LSZH Acid Gas Generation:
Passes IEC 60754-1 and 60754-2
LSZH Smoke Emission:
Passes IEC 61034-2
Cable > Communication, Control and Industrial > Low-Smoke, Zero-Halogen (LSZH)
Communication and Control Cable
300 V Foil Shielded, Multipair, LSZH
*Conductor color coding: 1 Red-Black, 2 Green-White, White/Red-White/Black, 4 White/Green-White/Yellow.
†0.009 (0.23) insulation thickness.
††0.008 (0.20) insulation thickness.
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
308
Cable > Communication, Control and Industrial > Multiconductor > Unshielded > 300 V
Communication and Control
300 V Unshielded, Multiconductor, PVC, PVC
UL AWM 2576 (150 V) VW-1
UL CM
CSA CMG FT4
Operating Temperature
-20°C to +80°C (AWM)
-20°C to +75°C (CM)
-20°C to +60°C (CMG)
Conductor Color Coding
Chart D (page 531)
Materials
Stranded or solid tinned copper
conductors
PVC insulation
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1172C 2 0.164 4.17 0.032 0.81
1173C 3 0.172 4.37 0.032 0.81
1174C 4 0.185 4.70 0.032 0.81
1175C 5 0.200 5.08 0.032 0.81
1176C 6 0.215 5.46 0.032 0.81
1177C 7 0.215 5.46 0.032 0.81
1178C 8 0.230 5.84 0.032 0.81
1179C 9 0.246 6.25 0.032 0.81
1180C 10 0.264 6.71 0.032 0.81
1181C 12 0.272 6.91 0.032 0.81
1181/15C 15 0.294 7.47 0.032 0.81
1181/20C 20 0.326 8.28 0.032 0.81
1181/25C 25 0.364 9.25 0.032 0.81
1181/30C 30 0.385 9.78 0.032 0.81
1181/40C 40 0.429 10.90 0.032 0.81
1181/50C 50 0.478 12.14 0.035 0.89
1181/60C 60 0.520 13.21 0.035 0.89
22 AWG (0.32 mm2)
Stranding: Solid
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1793C 2 0.157 3.99 0.032 0.81
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 309
Cable > Communication, Control and Industrial > Multiconductor > Unshielded > 300 V
Communication and Control
300 V Unshielded, Multiconductor, PVC, PVC
UL AWM 2509 VW-1
UL CM
CSA CMG FT4
Operating Temperature
-20°C to +80°C (AWM)
-20°C to +75°C (CM)
-20°C to +60°C (CMG)
Conductor Color Coding
Chart D (page 531)
Materials
Stranded tinned copper
conductors
PVC insulation
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1895C 2 0.180 4.57 0.020 0.51
1896C 3 0.191 4.85 0.020 0.51
1896/4C 4 0.209 5.31 0.020 0.51
1896/5C 5 0.230 5.84 0.020 0.51
1896/6C 6 0.251 6.38 0.020 0.51
1896/7C 7 0.251 6.38 0.020 0.51
1896/8C 8 0.273 6.93 0.020 0.51
1896/9C 9 0.301 7.65 0.023 0.58
1896/10C 10 0.320 8.13 0.020 0.51
1896/12C 12 0.331 8.41 0.020 0.51
1896/15C 15 0.382 9.70 0.030 0.76
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1897C 2 0.198 5.03 0.020 0.51
1898C 3 0.210 5.33 0.020 0.51
1898/4C 4 0.231 5.87 0.020 0.51
1898/5C 5 0.254 6.45 0.020 0.51
1898/6C 6 0.278 7.06 0.020 0.51
1898/7C 7 0.278 7.06 0.020 0.51
1898/8C 8 0.313 7.95 0.025 0.64
1898/9C 9 0.337 8.56 0.025 0.64
1898/10C 10 0.366 9.30 0.025 0.64
1898/12C 12 0.378 9.60 0.025 0.64
1898/15C 15 0.423 10.74 0.030 0.76
1898/19C 19 0.455 11.56 0.030 0.76
1898/25C 25 0.544 13.82 0.035 0.89
16 AWG (1.32 mm2)
Stranding 19/0.0117 (19 x 0.29 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1899C 2 0.222 5.64 0.020 0.51
1899/3C 3 0.236 5.99 0.020 0.51
1899/4C 4 0.260 6.60 0.020 0.51
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
310
Cable > Communication, Control and Industrial > Multiconductor > Unshielded > 300 V
Communication and Control
300 V Unshielded, Multiconductor, PVC, PVC
UL CL2 VW-1
CSA AWM I/II A/B FT1
Operating Temperature
-20°C to +80°C (AWM)
-20°C to +75°C (CL2)
Conductor Color Coding
Chart D (page 531)
Materials
Stranded tinned copper
conductors
PVC insulation
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
14 AWG (2.09 mm2)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.020 (0.51 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1891C 2 0.268 6.81 0.020 0.51
1891/3C 3 0.286 7.26 0.020 0.51
12 AWG (3.31 mm2)
Stranding: 65/30 (65 x 0.25 mm)
Insulation thickness: 0.020 (0.51 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1892C 2 0.312 7.92 0.023 0.58
1892/3C 3 0.333 8.46 0.023 0.58
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 311
Cable > Communication, Control and Industrial > Multiconductor > Unshielded > 600 V
Communication and Control
600 V Unshielded, Multiconductor, PVC, PVC
UL AWM 2463 VW-1
Operating Temperature
-20°C to +80°C
Conductor Color Coding
Chart F (page 532)
Materials
Stranded tinned copper
conductors
PVC insulation
Clear polyester wrap
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
16 AWG (1.32 mm2)
Stranding 19/0.0117 (19 x 0.29 mm)
Insulation Thickness 0.032 (0.81 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1064 4 0.395 10.03 0.047 1.19
1065 5 0.430 10.92 0.047 1.19
1067 7 0.468 11.89 0.047 1.19
1069 9 0.577 14.66 0.063 1.60
1072 12 0.640 16.26 0.063 1.60
1075 15 0.694 17.63 0.063 1.60
1079 19 0.749 19.02 0.065 1.65
1085 25 0.907 23.04 0.083 2.11
14 AWG (2.08 mm2)
Stranding (19 x 0.0147 (19 x 0.37 mm)
Insulation thickness: 0.047 (1.19 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1274 4 0.503 12.78 0.047 1.19
1275 5 0.584 14.83 0.063 1.60
1277 7 0.635 16.13 0.063 1.60
1279 9 0.744 18.90 0.065 1.60
1282 12 0.867 22.02 0.083 2.11
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
312
Cable > Communication, Control and Industrial > Multiconductor > Unshielded > 300 V
Communication and Control
300 V Unshielded, Multiconductor, IRR PVC, PVC
MIL-DTL-16878/1 (Type B)
UL AWM 2576 (150 V) VW-1
Operating Temperature
-55°C to +105°C (MIL)
-55°C to +80°C (AWM)
Conductor Color Coding
1 White, 2 Black, 3 Red, 4 Green
Materials
Stranded tinned copper
conductors
Irradiated PVC insulation
Clear polyester wrap
White PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
24 AWG (0.22 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
6622 2 0.155 3.94 0.032 0.81
6623 3 0.162 4.11 0.032 0.81
6624 4 0.173 4.39 0.032 0.81
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
6632 2 0.167 4.24 0.032 0.81
6633 3 0.175 4.44 0.032 0.81
6634 4 0.188 4.78 0.032 0.81
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
6642 2 0.183 4.65 0.032 0.81
6643 3 0.192 4.88 0.032 0.81
6644 4 0.207 5.26 0.032 0.81
18 AWG (0.89 mm2)
Stranding: 7/26 (7 x 0.40 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
6652 2 0.203 5.16 0.032 0.81
6653 3 0.214 5.44 0.032 0.81
6654 4 0.232 5.89 0.032 0.81
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 313
Cable > Communication, Control and Industrial > Multiconductor > Unshielded and Braid Shield > 300 V
Communication and Control
300 V Unshielded and Braid Shield, Multiconductor, PVC, PVC
UL AWM 2785 VW-1
UL CM
CSA CMG FT4
Operating Temperature
-20°C to +75°C (CM)
-20°C to +60°C (AWM, CMG)
Conductor Color Coding
See tables
Materials
Stranded tinned copper
conductors
PVC insulation
Tinned copper braid shield,
80% coverage
Slate PVC jacket
Availability
100 ft (30.5 m)*
500 ft (152 m)*
1000 ft (305 m)
*Parts 1243, 1243/4, and 1243/5 only
22 AWG Composite Shielded and Unshielded, UL AWM 2785, UL CM, and CSA CMG
22 AWG (0.35 mm2)
Stranding 7/30 (7 x 0.25 mm)
Insulation Thickness 0.016 (0.41 mm)
Part
No. Conductors
Nominal
Diameter Jacket
Thickness Configuration
Inch mm Inch mm Shielded Unshielded
1243 3 0.190 4.83 0.020 0.51 1 2
1243/4 4
0.185 x 0.285
4.70 x 7.24 0.020 0.51 2 2
1243/5 5
0.195 x 0.300
4.95 x 7.62 0.020 0.51 3 2
22 and 18 AWG Unshielded, UL CM and CSA CMG Only
22 AWG (0.35 mm2) 18 AWG (0.81 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm) 16/30 (16 x 0.25 mm)
0.018 (0.45 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
22 AWG 18 AWG Inch mm Inch mm
1826C 4 2 0.241 6.12 0.025 0.63
1827C 5 2 0.247 6.27 0.028 0.71
1828C 6 2 0.261 6.63 0.028 0.71
Conductor Color Coding
Shielded: 1 White, 2 Black, 3 Red
Unshielded: 1 Black, 2 Red
Conductor Color Coding
22 AWG: Chart I (page 533)
18 AWG: Chart D (page 531)
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
314
Cable > Communication, Control and Industrial > Multiconductor > Foil Shield > 300 V
Communication and Control
300 V Foil Shield, Multiconductor, PE, PVC
UL AWM 2092, 2093,
2094 VW-1
UL CMG
CSA CMG FT4
Operating Temperature
-20°C to +75°C (CMG)
-20°C to +60°C (AWM)
Conductor Color Coding
1 Black, 2 Red, 3 Natural,
4 Green
Materials
Stranded tinned copper
conductors
Polyethylene insulation
Aluminum/polyester foil shield,
25% overlap min.
Foil facing outward
Stranded tinned copper drain
wire (see table for sizes)
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m), spool or box
1000 ft (305 m), spool or box
*Color code: 1 black, 2 natural.
24 AWG (0.23 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.016 (0.41 mm)
24 AWG (0.22 mm2) drain wire
Part No. Conductors Nominal Diameter Jacket Thickness AWM
Inch mm Inch mm
2400C 2 0.156 3.96 0.020 0.51 2092
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
22 AWG (0.35 mm2) drain wire
Part No. Conductors Nominal Diameter Jacket Thickness AWM
Inch mm Inch mm
2401C* 2 0.168 4.27 0.020 0.51 2092
2402C 2 0.168 4.27 0.020 0.51 2092
2403C 3 0.178 4.52 0.020 0.51 2093
2404C 4 0.194 4.93 0.020 0.51 2094
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
20 AWG (0.50 mm2) drain wire
Part No. Conductors Nominal Diameter Jacket Thickness AWM
Inch mm Inch mm
2411C* 2 0.184 4.67 0.020 0.51 2092
2412C 2 0.184 4.67 0.020 0.51 2092
2413C 3 0.195 4.95 0.020 0.51 2093
2414C 4 0.213 5.41 0.020 0.51 2094
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
20 AWG (0.50 mm2) drain wire
Part No. Conductors Nominal Diameter Jacket Thickness AWM
Inch mm Inch mm
2421C* 2 0.202 5.13 0.020 0.51 2092
2422C 2 0.202 5.13 0.020 0.51 2092
2423C 3 0.214 5.44 0.020 0.51 2093
2424C 4 0.235 5.97 0.020 0.51 2094
16 AWG (1.32 mm2)
Stranding: 19/0.117 (19 x 0.30 mm)
Insulation thickness: 0.016 (0.41 mm)
18 AWG (0.81 mm2) drain wire
Part No. Conductors Nominal Diameter Jacket Thickness AWM
Inch mm Inch mm
2432C 2 0.226 5.74 0.020 0.51 2092
2433C 3 0.240 6.10 0.020 0.51 2093
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 315
Cable > Communication, Control and Industrial > Multiconductor > Foil Shield > 300 V
Communication and Control
300 V Foil Shield, Multiconductor, PE, PVC
UL CL2
CSA AWM I/II A/B FT4
Operating Temperature
-20°C to +75°C (CL2)
-20°C to +60°C (AWM)
Conductor Color Coding
1 Black, 2 Red, 3 Natural,
4 Green
Materials
Stranded tinned copper
conductors
Polyethylene insulation
Aluminum/polyester foil shield,
25% overlap min.
Foil facing outward
Stranded tinned copper drain
wire (see table for sizes)
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m), spool or box
1000 ft (305 m), spool or box
14 AWG (2.08 mm2)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.020 (0.51 mm)
16 AWG (1.32 mm2) drain wire
Part No. Conductors Nominal Diameter Jacket Thickness UL
Inch mm Inch mm
2442C 2 0.292 7.42 0.030 0.76 CL2
12 AWG (3.29 mm2)
Stranding: 65/30 (65 x 0.25 mm)
Insulation thickness: 0.020 (0.51 mm)
14 AWG (2.08 mm2) drain wire
Part No. Conductors Nominal Diameter Jacket Thickness UL
Inch mm Inch mm
2444C 2 0.330 8.38 0.030 0.76 CL2
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
316
Cable > Communication, Control and Industrial > Multiconductor > Foil Shield > 300 V
Communication and Control
300 V Foil Shield, Multiconductor, PP, PE, PVC/PVC
UL CM
VW-1
CSA CMG FT4
Operating Temperature
-20°C to +75°C (CM)
-20°C to +60°C (CMG)
Conductor Color Coding
1 White, 2 Black, 3 Red, 4 Green
1 Black, 2 Red, 3 White, 4 Green
Materials
Stranded tinned copper
conductors (except 2460C)
PP, PE, or PVC insulation
Aluminum/polyester foil shield,
25% overlap min.
Foil facing outward
1243/3C: foil facing inward
Stranded tinned copper
drain wire (except 2460C)
Slate PVC jacket
2461C: slate or black
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Polypropylene Insulation
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm) or solid
Insulation Thickness: 0.008 (0.20 mm)
Part
No. Conductors Nominal Diameter Jacket Thickness Configuration
Inch mm Inch mm Shielded Unshielded
2460C 2 (solid) 0.126 3.20 0.020 0.51 2 0
2461C 2 0.136 3.45 0.020 0.51 2 0
Polyethylene Insulation
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation Thickness: 0.014 (0.36 mm)
Part No. Conductors Nominal Diameter Jacket Thickness Configuration
Inch mm Inch mm Shielded Unshielded
1243/3C 3 0.210 5.33 0.030 0.76 2 1
2464C 4 0.165 4.19 0.020 0.51 2 2
PVC Insulation
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation Thickness: 0.015 (0.38 mm)
Part No. Conductors Nominal Diameter Jacket Thickness Configuration
Inch mm Inch mm Shielded Unshielded
2465C 4 0.240 6.10 0.030 0.76 2 2
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 317
Cable > Communication, Control and Industrial > Multiconductor > Foil Shield > 300 V
Communication and Control
300 V Foil Shield, Multiconductor, PVC, PVC
UL AWM 2576 (150 V) VW-1
UL CM
CSA CMG FT4
Operating Temperature
-20°C to +80°C (AWM)
-20°C to +75°C (CM)
-20°C to +60°C (CMG)
Conductor Color Coding
Chart D (page 531)
Materials
Stranded tinned copper
conductors
PVC insulation
Aluminum/polyester foil shield,
25% overlap min.
Foil facing outward
Stranded tinned copper drain
wire equal in size to conductor
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
24 AWG (0.23 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1212C 2 0.156 3.96 0.032 0.81
1213C 3 0.163 4.14 0.032 0.81
1214C 4 0.174 4.42 0.032 0.81
1215C 5 0.187 4.75 0.032 0.81
1216C 6 0.201 5.11 0.032 0.81
1217C 7 0.201 5.11 0.032 0.81
1218C 8 0.214 5.44 0.032 0.81
1219C 9 0.228 5.79 0.032 0.81
1219/10C 10 0.244 6.20 0.032 0.81
1219/12C 12 0.251 6.38 0.032 0.81
1219/15C 15 0.270 6.86 0.032 0.81
1219/20C 20 0.298 7.57 0.032 0.81
1219/25C 25 0.332 8.43 0.032 0.81
1219/37C 37 0.376 9.55 0.032 0.81
1219/40C 40 0.390 9.91 0.032 0.81
1219/50C 50 0.427 10.85 0.032 0.81
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1292C 2 0.168 4.27 0.032 0.81
1293C 3 0.176 4.47 0.032 0.81
1294C 4 0.189 4.80 0.032 0.81
1295C 5 0.204 5.18 0.032 0.81
1296C 6 0.219 5.56 0.032 0.81
1297C 7 0.219 5.56 0.032 0.81
1298C 8 0.234 5.94 0.032 0.81
1299C 9 0.250 6.35 0.032 0.81
1299/10C 10 0.268 6.81 0.032 0.81
1299/12C 12 0.276 7.01 0.032 0.81
1299/15C 15 0.298 7.57 0.032 0.81
1299/20C 20 0.330 8.38 0.032 0.81
1299/25C 25 0.368 9.35 0.032 0.81
1299/30C 30 0.389 9.88 0.032 0.81
1299/37C 37 0.418 10.62 0.032 0.81
1299/40C 40 0.433 11.00 0.032 0.81
1299/50C 50 0.482 12.24 0.035 0.89
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
318
Cable > Communication, Control and Industrial > Multiconductor > Foil Shield > 300 V
Communication and Control
300 V Foil Shield, Multiconductor, SR-PVC, PVC
UL AWM 2464 VW-1
UL CM
CSA CMG FT4
Operating Temperature
-20°C to +80°C (AWM)
-20°C to +75°C (CM)
-20°C to +60°C (CMG)
Conductor Color Coding
Chart F (page 532)
Materials
Stranded tinned copper
conductors
Semirigid PVC insulation
Aluminum/polyester foil shield,
25% overlap min.
Foil facing outward
Stranded tinned copper drain
wire equal in size to conductor
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
24 AWG (0.22 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
6300/3* 3 0.163 4.14 0.032 0.81
6300/4* 4 0.174 5.44 0.032 0.81
6305 5 0.187 4.75 0.032 0.81
6306* 6 0.201 5.11 0.032 0.81
6300/8* 8 0.214 5.44 0.032 0.81
6300/10* 10 0.244 6.20 0.032 0.81
6307 15 0.270 6.86 0.032 0.81
6308 20 0.298 7.57 0.032 0.81
6309 25 0.332 8.43 0.032 0.81
6310 30 0.366 9.30 0.040 1.02
6311 40 0.406 10.31 0.040 1.02
6312 50 0.453 11.51 0.045 1.14
Mutual capacitance: 32 pF/ft (105 pF/m)
Ground capacitance: 58 pF/ft (190 pF/m)
*Color coding: 1 Black, 2 White, 3 Red, 4 Green, 5 Brown, 6 Blue, 7 Orange, 8 Yellow, 9 Violet, 10 Slate.
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 319
Cable > Communication, Control and Industrial > Multiconductor > Spiral Shield > 300 V
Communication and Control
300 V Spiral Shield, Multiconductor, PVC, PVC
AWM 2095
AWM 1108 (Single-conductor
cables)
Operating Temperature
-20°C to +80°C
Conductor Color Coding
1 Black, 2 Red, 3 White, 4 Green,
5 Yellow, 6 Blue
Materials
Stranded tinned copper
conductors
PVC insulation
Clear polyester wrap
(multiconductor only)
Bare copper spiral shield,
95% coverage
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2254/1 1 0.112 2.84 0.020 0.51
2254 2 0.177 4.50 0.020 0.51
2254/3 3 0.187 4.75 0.020 0.51
2254/4 4 0.206 5.23 0.020 0.51
2254/6 6 0.243 6.17 0.020 0.51
20 AWG (0.56 mm2)
Stranding: 10/30 (10 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2256/1 1 0.119 3.02 0.020 0.51
2256 2 0.191 4.85 0.020 0.51
2256/3 3 0.202 5.13 0.020 0.51
2256/4 4 0.223 5.66 0.020 0.51
2256/6 6 0.264 6.71 0.020 0.51
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2258/1 1 0.129 3.28 0.020 0.51
2258 2 0.214 5.44 0.020 0.51
2258/3 3 0.226 5.74 0.020 0.51
2258/4 4 0.247 6.27 0.020 0.51
16 AWG (1.32 mm2)
Stranding: 26/30 (26 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2260 2 0.240 6.10 0.020 0.51
2260/3 3 0.254 6.45 0.020 0.51
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
320
Cable > Communication, Control and Industrial > Multiconductor > Braid Shield > 600 V
Communication and Control
600 V Braid Shield, Multiconductor, PVC, PVC
MIL-DTL-16878/1 (Type B)
Operating Temperature
-55°C to +105°C
Conductor Color Coding
Chart F (page 532)
Materials
Stranded tinned copper
conductors
PVC insulation
Clear polyester wrap
Tinned copper braid shield,
90% coverage
Slate PVC jacket
Availability
100 ft (30.5 m)
1000 ft (305 m)
28 AWG (0.09 mm2)
Stranding: 7/36 (7 x 0.13 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
3302 2 0.119 3.02 0.012 0.30
3303 3 0.124 3.15 0.012 0.30
3304 4 0.134 3.40 0.012 0.30
3306 6 0.161 4.09 0.015 0.38
3308 8 0.171 4.34 0.015 0.38
3310 10 0.201 5.11 0.018 0.46
3312 12 0.206 5.23 0.018 0.46
3315 15 0.236 5.99 0.020 0.51
3320 20 0.261 6.63 0.022 0.56
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 321
Cable > Communication, Control and Industrial > Multipair > Braid Shield > 600 V
Communication and Control
600 V Braid Shield, Multiconductor, PVC/Nylon, PVC
MIL-DTL-16878/17 (Type B/N)
Operating Temperature
-55°C to +105°C
Conductor Color Coding
1 White, 2 Black, 3 Red, 4 Green
(unless otherwise noted)
Materials
Stranded tinned copper
conductors
PVC/nylon insulation
Clear polyester wrap
(multiconductor only)
Tinned copper braid shield,
90% coverage
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
26 AWG (0.14 mm2)
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm) PVC/0.003 (0.08 mm) nylon
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
3200 1 0.087 2.21 0.010 0.25
3201 2 0.143 3.63 0.014 0.36
3202 3 0.150 3.81 0.014 0.36
3203 4 0.166 4.22 0.016 0.41
24 AWG (0.24 mm2)
Stranding: 19/36 (19 x 0.13 mm)
Insulation thickness: 0.010 (0.25 mm) PVC/0.003 (0.08 mm) nylon
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
3210 1 0.093 2.36 0.010 0.25
3211 2 0.159 4.04 0.016 0.41
3212 3 0.167 4.24 0.016 0.41
3213 4 0.182 4.62 0.017 0.43
22 AWG (0.38 mm2)
Stranding: 19/34 (19 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm) PVC/0.003 (0.08 mm) nylon
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
3220 1 0.100 2.54 0.010 0.25
3221 2 0.173 4.39 0.016 0.41
3222 3 0.184 4.67 0.017 0.43
3223 4 0.203 5.16 0.019 0.49
3335* 5 0.228 5.79 0.020 0.51
3336* 6 0.246 6.25 0.020 0.64
3337* 8 0.274 6.96 0.025 0.64
*Color code chart F.
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
322
Cable > Communication, Control and Industrial > Multipair > Braid Shield > 600 V
Communication and Control
600 V Braid Shield, Multipair, PVC/Nylon, PVC
MIL-DTL-16878/17 (Type B/N)
Operating Temperature
-55°C to +105°C
Conductor Color Coding
1 White, 2 Black, 3 Red, 4 Green
(unless otherwise noted)
Materials
Stranded tinned copper
conductors
PVC/nylon insulation
Clear polyester wrap
(multiconductor only)
Tinned copper braid shield,
90% coverage
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
20 AWG (0.61 mm2)
Stranding: 19/32 (19 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm) PVC/0.003 (0.08 mm) nylon
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
3230 1 0.108 2.74 0.010 0.25
3231 2 0.195 4.95 0.019 0.49
3232 3 0.205 5.21 0.019 0.49
3233 4 0.227 5.77 0.021 0.53
18 AWG (0.96 mm2)
Stranding: 19/30 (19 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm) PVC/0.003 (0.08 mm) nylon
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
3240 1 0.122 3.10 0.012 0.30
3241 2 0.219 5.56 0.021 0.53
3242 3 0.233 5.92 0.022 0.56
3243 4 0.261 6.63 0.023 0.58
16 AWG (1.23 mm2)
Stranding: 19/29 (19 x 0.29 mm)
Insulation thickness: 0.010 (0.25 mm) PVC/0.003 (0.08 mm) nylon
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
3245 1 0.136 0.136 0.016 0.41
3246 2 0.241 0.241 0.023 0.58
3247 3 0.254 0.254 0.023 0.58
3248 4 0.279 0.279 0.025 0.64
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 323
Cable > Communication, Control and Industrial > Multiconductor > Braid Shield > 300 V
Communication and Control
300 V Braid Shield, Multiconductor, PVC, PVC
UL AWM 2095 VW-1
UL AWM 1108
(Single-Conductor Cables)
UL CM
CSA CMG FT4
Operating Temperature
-20°C to +80°C (AWM)
-20°C to +75°C (CM)
-20°C to +60°C (CMG)
Conductor Color Coding
Chart D (page 531)
Materials
Stranded or solid tinned
copper conductors
PVC insulation
Clear polyester wrap
(multiconductor only)
Bare copper braid shield,
75% coverage
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
22 AWG (0.32 mm2)
Stranding: Solid
Insulation thickness: 0.020 (0.51 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1775C 2 0.195 4.95 0.020 0.51
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1735 1 0.124 3.15 0.020 0.51
1736C 2 0.189 4.80 0.020 0.51
1737C 3 0.199 5.05 0.020 0.51
1738C 4 0.215 5.46 0.020 0.51
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1741C 2 0.205 5.21 0.020 0.51
1742C 3 0.216 5.49 0.020 0.51
1743C 4 0.234 5.94 0.020 0.51
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1745 1 0.141 3.58 0.020 0.51
1746C 2 0.223 5.66 0.020 0.51
1747C 3 0.235 5.97 0.020 0.51
1747/4C 4 0.256 6.50 0.020 0.51
16 AWG (1.32 mm2)
Stranding: 19/0.0117 (19 x 0.30 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1748C 2 0.247 6.27 0.020 0.51
1749C 3 0.261 6.63 0.020 0.51
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
324
Cable > Communication, Control and Industrial > Multiconductor > Braid Shield > 450 V
Communication and Control
450 V Braid Shield, Multiconductor, PVC, PVC
Operating Temperature
-20°C to +80°C
Conductor Color Coding
Chart D (page 531)
Materials
Stranded tinned copper
conductors
PVC insulation
Clear polyester wrap
Bare copper braid shield,
75% coverage
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
14 AWG (2.08 mm2)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.020 (0.51 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1750 2 0.299 7.59 0.020 0.51
1751 3 0.317 8.05 0.020 0.51
12 AWG (3.29 mm2)
Stranding: 65/30 (65 x 0.25 mm)
Insulation thickness: 0.020 (0.51 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1760 2 0.337 8.56 0.020 0.51
1761 3 0.358 9.09 0.020 0.51
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 325
Cable > Communication, Control and Industrial > Multiconductor > Braid Shield > 600 V
Communication and Control
600 V Braid Shield, Multiconductor, IRR PVC, PVC
MIL-DTL-16878/1 (Type B)
Operating Temperature
-55°C to +105°C
Conductor Color Coding
Chart G (page 532)
Materials
Stranded tinned copper
conductors
Irradiated PVC insulation
Clear polyester wrap
Tinned copper braid shield,
90% coverage
White PVC jacket
Availability
1000 ft (305 m)
24 AWG (0.22 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
7622 2 0.163 4.14 0.025 0.64
7623 3 0.170 4.32 0.025 0.64
7624 4 0.181 4.60 0.025 0.64
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
7631 1 0.122 3.10 0.025 0.64
7632 2 0.175 4.45 0.025 0.64
7633 3 0.183 4.65 0.025 0.64
7634 4 0.196 4.98 0.025 0.64
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
7661 1 0.130 3.30 0.025 0.64
7662 2 0.191 4.85 0.025 0.64
7663 3 0.200 5.08 0.025 0.64
7664 4 0.215 5.46 0.025 0.64
18 AWG (0.89 mm2)
Stranding: 7/26 (7 x 0.40 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
7671 1 0.140 3.56 0.025 0.64
7672 2 0.211 5.35 0.025 0.64
7673 3 0.222 5.64 0.025 0.64
7674 4 0.240 6.09 0.025 0.64
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
326
Cable > Communication, Control and Industrial > Multiconductor > Braid Shield > 1000 V
Communication and Control
1000 V Braid Shield, Multiconductor, PVC, PVC
MIL-DTL-16878/2 (Type C)
Operating Temperature
-55°C to +105°C
Conductor Color Coding
Chart F (page 532)
Materials
Stranded tinned copper
conductors
PVC insulation
Clear polyester wrap
Tinned copper braid shield,
90% coverage
Slate PVC jacket
Availability
100 ft (30.5 m)
1000 ft (305 m)
18 AWG (0.96 mm2)
Stranding: 19/30 (19 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
3405 5 0.303 7.70 0.025 0.64
3408 8 0.364 9.25 0.030 0.76
3410 10 0.429 10.90 0.035 0.89
3412 12 0.442 11.23 0.035 0.89
3415 15 0.488 12.40 0.040 1.02
3420 20 0.550 13.97 0.045 1.14
3430 30 0.667 16.94 0.055 1.40
16 AWG (1.23 mm2)
Stranding: 19/29 (19 x 0.29 mm)
Insulation thickness: 0.018 (0.45 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
3444 4 0.316 8.03 0.031 0.79
3446 6 0.376 9.55 0.034 0.86
3450 10 0.487 12.37 0.044 1.12
3452 12 0.509 12.93 0.048 1.22
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 327
Cable > Communication, Control and Industrial > Multiconductor > Braid or Spiral Shield
Communication and Control
Braid or Spiral Shield, Multiconductor, PE, PVC
Microphone Cable
Operating Temperature
-20°C to +60°C
Conductor Color Coding
1-White, 2-Black
Materials
Stranded tinned copper
conductors
Polyethylene insulation
Clear polyester wrap
(multiconductor only)
Braided tinned copper or
spiral wrapped tinned copper
shield, 90% coverage
(85% for part no. 1712)
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
1-Conductor Cable for High-Impedance Microphones
Part No. Voltage
Rating
Wire Size Stranding Nominal
Diameter Shield
Jacket
Thickness Insulation
Thickness Capacitance
AWG mm2AWG mm Inch mm Inch mm Inch mm pF/ft pF/m
1706* 4000 20 0.52 26/34 26 x 0.16 0.182 4.62 Braid 0.030 0.76 0.031 0.79 38 125
1703 3500 24 0.20 10/34 10 x 0.16 0.146 3.71 Braid 0.030 0.76 0.020 0.50 36 118
1702** 1000 26 0.14 7/34 7 x 0.16 0.101 2.57 Spiral 0.020 0.51 0.016 0.41 35 115
1705 1000 24 0.20 10/34 10 x 0.16 0.106 2.69 Spiral 0.020 0.51 0.016 0.41 41 135
2-Conductor Cable for Low-Impedance Microphones
Part No. Voltage
Rating
Wire Size Stranding Nominal
Diameter Shield
Jacket
Thickness Insulation
Thickness Capacitance*
AWG mm2AWG mm Inch mm Inch mm Inch mm pF/ft pF/m
1709 1000 24 0.20 10/34 10 x 0.16 0.185 4.70 Spiral 0.030 0.76 0.016 0.41 32 105
1710 1000 22 0.38 19/34 19 x 0.16 0.239 6.07 Braid 0.025 0.64 0.025 0.63 30 98
1712 600 20 0.52 26/34 26 x 0.16 0.221 5.61 Braid 0.030 0.76 0.015 0.38 44 144
*Capacitance between one conductor and remaining conductors connected to shield.
*UL AWM 1150, 300 V.
**1702 has 3 strands of tinned copper and 4 strands of tinned Copperweld.
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
328
Cable > Communication, Control and Industrial > Multiconductor > Braid Shield > 600 V
Communication and Control
600 V Braid Shield, Multiconductor, PE, PVC
Audio Cable
Operating Temperature
-20°C to +60°C
Conductor Color Coding
1771: White, blue
Black, red, or orange jacket
1772: White, blue, white, blue
Black, brown, slate, or
yellow jacket
Part
No. Conductors Wire Size Stranding Nominal
Diameter Shield
Jacket
Thickness Insulation
Thickness Capacitance
AWG mm2AWG mm Inch mm Inch mm Inch mm pF/ft pF/m
1771 2 23 0.29 60/40 60 x 0.08 0.243 6.17 Braid 0.040 1.01 0.020 0.51 17.9 58.7
1772 4 25 0.20 40/40 40 x 0.08 0.239 6.07 Braid 0.044 1.11 0.014 0.35 18 69.1
Materials
Bare copper conductors
Polyethylene insulation
Tinned copper braid shield,
95% coverage
PVC jacket
Availability
100 ft (30.5 m)
1000 ft (305 m)
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 329
Cable > Communication, Control and Industrial > Multiconductor > Braid Shield > 600 V
Communication and Control
600 V Multiconductor, PE, PVC
Braid Shield
Operating Temperature
-20°C to +60°C
Conductor Color Coding
Chart H (page 533)
Materials
Stranded tinned copper
conductors
Polyethylene insulation
Clear polyester wrap
Braided tinned copper shield,
85% coverage
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
20 AWG (0.52 mm2)
Stranding: 26/34 (26 x 0.16 mm)
Insulation thickness: 0.015 (0.38 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1712 2 0.221 5.61 0.030 0.76
1713 3 0.248 6.30 0.035 0.88
1715 4 0.266 6.76 0.035 0.88
1716 5 0.285 7.24 0.035 0.88
1717 6 0.306 7.77 0.035 0.88
1719 8 0.327 8.31 0.035 0.88
1721 10 0.373 9.47 0.035 0.88
1723 12 0.384 9.75 0.035 0.88
1726 15 0.421 10.69 0.035 0.88
1728 20 0.462 11.73 0.035 0.88
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
330
Cable > Communication, Control and Industrial > Multiconductor > Braid Shield > 600 V
Communication and Control
600 V Multiconductor, Rubber, Polychloroprene
Braid Shield
Operating Temperature
-20°C to +60°C
Conductor Color Coding
Chart H (page 533)
Materials
Stranded tinned copper
conductors
EPDM rubber insulation
Clear polyester wrap
Tinned copper braid shield,
85% coverage
Black polychloroprene jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
18 AWG (0.82 mm2)
Stranding: 41/34 (41 x 0.16 mm)
Insulation thickness: 0.020 (0.51 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1450 2 0.298 7.57 0.045 1.14
1454 6 0.392 9.96 0.045 1.14
16AWG (1.31 mm2)
Stranding: 65/34 (65 x 0.16 mm)
Insulation thickness: 0.026 (0.65 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
1450/16 2 0.327 8.31 0.036 0.91
1451/16 3 0.350 8.89 0.037 0.94
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 331
Cable > Communication, Control and Industrial > Multiconductor > Braid Shield > 600 V
Communication and Control
600 V Multiconductor, PTFE, FEP
Braid Shield
MIL-DTL-16878/4 (Type E)
NEMA HP3-EXBEE
Operating Temperature
-55°C to +200°C
Conductor Color Coding
Chart G (page 532)
Materials
Stranded silver-plated copper
conductors
PTFE insulation
Clear polyester wrap
Silver-plated copper braid
shield, 90% coverage
White FEP jacket
Availability
100 ft (30.5 m)
1000 ft (305 m)*
*May contain multiple lengths
24 AWG (0.24 mm2)
Stranding: 19/36 (19 x 0.13 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2831 1 0.087 2.21 0.010 0.25
2831/2 2 0.132 3.35 0.010 0.25
2831/3 3 0.139 3.53 0.010 0.25
22 AWG (0.38 mm2)
Stranding: 19/34 (19 x 0.16 mm)
Insulation thickness: 0.009 (0.23 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2834 1 0.092 2.34 0.010 0.25
2834/2 2 0.142 3.61 0.010 0.25
2834/3 3 0.154 3.91 0.012 0.30
20 AWG (0.62 mm2)
Stranding: 19/32 (19 x 0.20 mm)
Insulation thickness: 0.009 (0.23 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2837/2 2 0.162 4.11 0.012 0.30
2837/3 3 0.171 4.34 0.012 0.30
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
332
Cable > Communication, Control and Industrial > Multiconductor > Braid Shield > 600 V
Communication and Control
600 V Multiconductor, TFE, Fiberglass
Braid Shield
MIL-DTL-16878/4 (Type E)
NEMA HP3-EXBEE
Operating Temperature
-55°C to +200°C
Conductor Color Coding
Chart G (page 532)
Materials
Stranded silver-plated copper
conductors
TFE insulation
Silver-plated copper braid
shield, 90% coverage
White PTFE-impregnated
fiberglass jacket
Availability
100 ft (30.5 m)
1000 ft (305 m)*
*May contain multiple lengths
24 AWG (0.24 mm2)
Stranding: 19/36 (19 x 0.13 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2811 1 0.100 2.54 0.012 0.30
2811/2 2 0.145 3.68 0.012 0.30
2811/3 3 0.152 3.86 0.012 0.30
2811/4 4 0.164 4.17 0.012 0.30
2811/5 5 0.177 4.50 0.012 0.30
2811/7 7 0.191 4.85 0.012 0.30
22 AWG (0.38 mm2)
Stranding: 19/34 (19 x 0.16 mm)
Insulation thickness: 0.009 (0.23 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2814/2 2 0.155 3.94 0.012 0.30
2814/4 4 0.176 4.47 0.012 0.30
2814/6 6 0.206 5.23 0.012 0.30
20 AWG (0.62 mm2)
Stranding: 19/32 (19 x 0.20 mm)
Insulation thickness: 0.009 (0.23 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2817/2 2 0.171 4.34 0.012 0.30
2817/3 3 0.180 4.57 0.012 0.30
2817/4 4 0.195 4.95 0.012 0.30
2817/5 5 0.212 5.38 0.012 0.30
2817/6 6 0.230 5.84 0.012 0.30
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 333
Cable > Communication, Control and Industrial > Multipair > Braid Shield > 600 V
Communication and Control
600 V Multiconductor, TFE, Fiberglass
Braid Shield
MIL-DTL-16878/4 (Type E)
NEMA HP3
Operating Temperature
-55°C to +200°C
Conductor Color Coding
Chart G (page 532)
Materials
Stranded silver-plated copper
conductors
TFE insulation
Silver-plated copper braid
shield, 90% coverage
White PTFE-impregnated
fiberglass jacket
Availability
100 ft (30.5 m)
1000 ft (305 m)*
*May contain multiple lengths
18 AWG (0.96 mm2)
Stranding: 19/30 (19 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2819 1 0.125 3.18 0.012 0.30
2819/2 2 0.195 4.95 0.012 0.30
2819/3 3 0.206 5.23 0.012 0.30
2819/4 4 0.224 5.69 0.012 0.30
2819/5 5 0.245 6.22 0.012 0.30
16 AWG (1.32 mm2)
Stranding: 19/29 (19 x 0.29 mm)
Insulation thickness: 0.012 (0.30 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2820 1 0.135 3.43 0.012 0.30
2820/2 2 0.215 5.46 0.012 0.30
2820/3 3 0.228 5.79 0.012 0.30
2820/4 4 0.249 6.32 0.012 0.30
14 AWG (1.23 mm2)
Stranding: 19/27 (19 x 0.36 mm)
Insulation thickness: 0.012 (0.30 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2804/2 1 0.245 6.22 0.012 0.30
2804/3 2 0.260 6.60 0.012 0.30
12 AWG (3.08 mm2)
Stranding: 19/25 (19 x 0.46 mm)
Insulation thickness: 0.012 (0.30 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2803/2 2 0.283 7.19 0.012 0.30
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
334
Cable > Communication, Control and Industrial > Multiconductor > Braid Shield > 600 V
Communication and Control
600 V Multiconductor, PTFE, PTFE Tape
Braid Shield
MIL-DTL-16878/4 (Type E)
NEMA HP3-EXBEE
Operating Temperature
-55°C to +200°C
Conductor Color Coding
Chart G (page 532)
Materials
Stranded silver-plated copper
conductors
PTFE insulation
Silver-plated copper braid
shield, 90% coverage
White PTFE tape jacket
Availability
100 ft (30.5 m)
1000 ft (305 m)*
*May contain multiple lengths
24 AWG (0.24 mm2)
Stranding: 19/36 (19 x 0.13 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2821 1 0.087 2.21 0.010 0.25
2821/2 2 0.136 3.45 0.012 0.30
2821/3 3 0.143 3.63 0.012 0.30
2821/4 4 0.155 3.94 0.012 0.30
2821/5 5 0.168 4.27 0.012 0.30
2821/6 6 0.182 4.62 0.012 0.30
22 AWG (0.38 mm2)
Stranding: 19/34 (19 x 0.16 mm)
Insulation thickness: 0.009 (0.23 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2824 1 0.092 2.34 0.010 0.25
2824/2 2 0.146 3.71 0.012 0.30
2824/3 3 0.154 3.91 0.012 0.30
2824/4 4 0.167 4.24 0.012 0.30
2824/5 5 0.182 4.62 0.012 0.30
2824/6 6 0.193 4.90 0.012 0.30
20 AWG (0.62 mm2)
Stranding: 19/32 (19 x 0.20 mm)
Insulation thickness: 0.009 (0.23 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2827 1 0.100 2.54 0.010 0.25
2827/2 2 0.158 4.01 0.012 0.30
2827/3 3 0.171 4.34 0.012 0.30
2827/4 4 0.186 4.72 0.012 0.30
2827/5 5 0.203 5.16 0.012 0.30
2827/6 6 0.221 5.61 0.012 0.30
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 335
18 AWG (0.96 mm2)
Stranding: 19/30 (19 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2829/2 2 0.186 4.72 0.012 0.30
2829/3 3 0.197 5.00 0.012 0.30
2829/4 4 0.215 5.46 0.012 0.30
Cable > Communication, Control and Industrial > Multipair > Braid Shield > 600 V
Communication and Control
600 V Multiconductor, PTFE, PTFE Tape
Braid Shield
MIL-DTL-16878/4 (Type E)
NEMA HP3-EXBEE
Operating Temperature
-55°C to +200°C
Conductor Color Coding
Chart G (page 532)
Materials
Stranded silver-plated copper
conductors
PTFE insulation
Silver-plated copper braid
shield, 90% coverage
White PTFE tape jacket
Availability
100 ft (30.5 m)
1000 ft (305 m)*
*May contain multiple lengths
16 AWG (1.23 mm2)
Stranding: 19/29 (19 x 0.29 mm)
Insulation thickness: 0.012 (0.30 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
2826 1 0.122 3.10 0.010 0.25
2826/2 2 0.206 5.23 0.012 0.30
2826/3 3 0.219 5.56 0.012 0.30
2826/4 4 0.240 6.10 0.012 0.30
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
336
Cable > Communication, Control and Industrial > Multiconductor > Foil/Braid Shield > 300 V
Communication and Control
300 V Multiconductor, SR-PVC, PVC
Foil/Braid Shield
UL AWM 2464 VW-1
UL CL2
CSA CMG FT4
Operating Temperature
-20°C to +80°C (AWM)
-20°C to +75°C (CL2)
-20°C to +60°C (CMG)
Conductor Color Coding
Chart D (page 531)
Materials
Stranded tinned copper
conductors
Semirigid PVC insulation
Foil + braid shield
Aluminum/polyester/aluminum
foil shield, 25% overlap min.
Foil facing outward
Stranded tinned copper
drain wire equal in size to
the conductor
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
28 AWG (0.08 mm2)
Stranding: 7/36 (7 x 0.13 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
3463* 3 0.171 4.34 0.035 0.89
3464C 4 0.181 4.60 0.035 0.89
3465C 5 0.191 4.85 0.035 0.89
3466C 6 0.202 5.13 0.035 0.89
3467C 7 0.202 5.13 0.035 0.89
3468C 8 0.212 5.38 0.035 0.89
3469C 9 0.223 5.66 0.035 0.89
3470C 10 0.236 5.99 0.035 0.89
3470/15C 15 0.267 6.78 0.035 0.89
3470/25C 25 0.312 7.92 0.035 0.89
3470/37C 37 0.347 8.81 0.035 0.89
3470/50C 50 0.397 10.08 0.035 0.89
*UL AWM 2464/CSA CMG only.
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 337
Cable > Communication, Control and Industrial > Multiconductor > Foil/Braid Shield > 300 V
Low Capacitance Data Cable
300 V Multiconductor, FPP, PVC
Foil/Braid Shield
UL AWM 2919 (30 V) VW-1
UL CL2
CSA CMG FT4
Operating Temperature
-20°C to +80°C (AWM)
-20°C to +75°C (CL2)
-20°C to +60°C (CMG)
Conductor Color Coding
Chart D (page 531) for
3-conductor to 9-conductor
cables
Chart F (page 532) for
25-conductor cables
Materials
Stranded tinned copper
conductors
Foam polypropylene insulation
Foil + braid shield
Aluminum/polyester/aluminum
foil shield, 25% overlap min.
Foil facing outward
Stranded tinned copper drain
wire equal in size to conductor
Tinned copper braid shield,
65% coverage
Slate PVC jacket
Availability
1000 ft (305 m)
28 AWG (0.08 mm2)
Stranding: 7/36 (7 x 0.13 mm)
Insulation thickness: 0.013 (0.33 mm)
Part No.* Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
3483 3 0.184 4.67 0.035 0.89
3484C 4 0.195 4.95 0.035 0.89
3488C 8 0.232 5.89 0.035 0.89
3489C 9 0.245 6.22 0.035 0.89
3490/25C 25 0.348 8.84 0.035 0.89
Mutual capacitance: 12 pF/ft (39.4 pF/m)
Ground capacitance: 20 pF/ft (65.6 pF/m)
*C suffix part no. are CL2 approved.
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
338
Cable > Communication, Control and Industrial > Multiconductor > Overall Foil/Braid Shield > 300 V
Communication and Control
300 V Multiconductor, SR-PVC, PVC
Overall Foil/Braid Shield
UL AWM 2464 VW-1
UL CM
CSA CMG FT4
Operating Temperature
-20°C to +80°C (AWM)
-20°C to +75°C (CM)
-20°C to +60°C (CMG)
Conductor Color Coding
Chart F (page 532) for
15-conductor through
50-condcutor cables
See table below for 3-conductor
through 10-conductor cables
Materials
Stranded tinned copper
conductors
Semirigid PVC insulation
Foil + braid shield
Aluminum/polyester foil shield,
25% overlap min.
Foil facing outward
Stranded tinned copper drain
wire, 24 AWG (0.22 mm2),
7/32 (7 x 0.22 mm)
Tinned copper braid,
65% coverage
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
24 AWG (0.22 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
6327 3 0.185 4.70 0.032 0.81
6328 4 0.196 4.98 0.032 0.81
6329 5 0.209 5.31 0.032 0.81
6330 6 0.223 5.66 0.032 0.81
6331 7 0.223 5.66 0.032 0.81
6332 8 0.236 5.99 0.032 0.81
6333 9 0.250 6.35 0.032 0.81
6334 10 0.266 6.76 0.032 0.81
6335 15 0.292 7.42 0.032 0.81
6336 25 0.354 8.99 0.032 0.81
6337 37 0.398 10.11 0.032 0.81
6338 50 0.449 11.40 0.032 0.81
Mutual capacitance: 32 pF/ft (105 pF/m)
Ground capacitance: 58 pF/ft (190 pF/m)
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
6339 3 0.198 5.03 0.032 0.81
6340 4 0.211 5.36 0.032 0.81
6341 5 0.226 5.74 0.032 0.81
6342 6 0.241 6.12 0.032 0.81
6343 7 0.241 6.12 0.032 0.81
6344 8 0.256 6.50 0.032 0.81
6345 9 0.272 6.91 0.032 0.81
6346 10 0.290 7.37 0.032 0.81
6347 15 0.320 8.13 0.032 0.81
6348 25 0.390 9.91 0.032 0.81
6349 37 0.440 11.18 0.032 0.81
6350 50 0.540 13.72 0.053 1.35
Mutual capacitance: 36 pF/ft (118 pF/m)
Ground capacitance: 65 pF/ft (213 pF/m)
Color Coding: 3 through 10 Conductors
1 Black 6 Blue
2 White 7 Orange
3 Red 8 Yellow
4 Green 9 Violet
5 Brown 10 Slate
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 339
Cable > Communication, Control and Industrial > Multiconductor > Foil/Braid Shield > 300 V
Communication and Control
300 V Foil/Braid Shield, Multiconductor, FPE, PVC
Low Capacitance Data Cable
UL AWM 2919 (30 V) VW-1
UL CM
CSA CMH FT1
Operating Temperature
-20°C to +80°C (AWM)
-20°C to +75°C (CM)
-20°C to +60°C (CMH)
Conductor Color Coding
Chart F (page 532) for 15
through 37 conductors. Other
parts, see table at right.
Materials
Stranded tinned copper
conductors
Foam polyethylene insulation
Foil + braid shield
Aluminum/polyester foil shield,
25% overlap min.
Foil facing outward
Stranded tinned copper drain
wire equal in size to conductor
Tinned copper braid,
65% coverage
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
24 AWG (0.22 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Conductors Nominal Diameter Jacket Thickness
Inch mm Inch mm
6351 3 0.217 5.51 0.035 0.89
6352 4 0.231 5.87 0.035 0.89
6353 5 0.248 6.30 0.035 0.89
6354 6 0.265 6.73 0.035 0.89
6355 7 0.265 6.73 0.035 0.89
6356 8 0.282 7.16 0.035 0.89
6357 9 0.300 7.62 0.035 0.89
6358 10 0.320 8.13 0.035 0.89
6359 15 0.353 8.97 0.035 0.89
6360 25 0.432 10.97 0.035 0.89
6361 37 0.514 13.06 0.048 1.22
Mutual capacitance: 12 pF/ft (39.4 pF/m)
Ground capacitance: 22 pF/ft (72.2 pF/m)
1 Black 5 Brown 9 Violet
2 White 6 Blue 10 Slate
3 Red 7 Orange
4 Green 8 Yellow
Color Coding
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
340
Cable > Communication, Control and Industrial > Multipair > Unshielded > 300 V
Communication and Control
300 V Unshielded, Multipair, PVC, PVC
UL AWM 2464, 2576 VW-1
UL CM
CSA CMG FT4
Operating Temperature
-20°C to +80°C (AWM)
-20°C to +75°C (CM)
-20°C to +60°C (CMG)
Conductor Color Coding
Chart A (page 528)
Materials
Stranded tinned copper
conductors
PVC insulation
Slate PVC jacket
Availability
1000 ft (305 m)
22 AWG (0.32 mm2)
Stranding: Solid
Insulation thickness: 0.010 (0.25 mm)
Part No. Pairs Nominal Diameter Jacket Thickness
Inch mm Inch mm
1300C 1 0.157 3.99 0.032 0.81
1302C 2 0.215 5.46 0.032 0.81
1304C 3 0.226 5.74 0.032 0.81
1305C 4 0.246 6.25 0.032 0.81
1306C 5 0.267 6.78 0.032 0.81
1307C 6 0.289 7.34 0.032 0.81
1308/11C 11 0.362 9.19 0.032 0.81
1309C 13 0.382 9.70 0.032 0.81
1310C 16 0.414 10.52 0.032 0.81
1313C 27 0.537 13.64 0.040 1.02
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Pairs Nominal Diameter Jacket Thickness
Inch mm Inch mm
1317C 2 0.231 5.87 0.032 0.81
1318C 3 0.244 6.20 0.032 0.81
1319C 4 0.265 6.73 0.032 0.81
1320C 5 0.289 7.34 0.032 0.81
1322C 6 0.320 8.13 0.035 0.89
1323C 9 0.371 9.42 0.035 0.89
1324C 11 0.401 10.19 0.035 0.89
1325C 12 0.414 10.52 0.035 0.89
1327C 15 0.460 11.68 0.040 1.02
1327/19C 19 0.493 12.52 0.040 1.02
18AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Pairs Nominal Diameter Jacket Thickness
Inch mm Inch mm
1131C 1 0.225 5.72 0.032 0.81
1132C 2 0.332 8.43 0.035 0.89
1133C 3 0.356 9.04 0.037 0.94
1134C 4 0.396 10.06 0.040 1.02
1135C 5 0.444 11.28 0.045 1.14
1136C 6 0.484 12.29 0.045 1.14
1138C 8 0.534 13.56 0.050 1.27
1139C 9 0.584 14.83 0.055 1.40
1149C 19 0.791 20.09 0.070 1.78
UL AWM 2464
UL AWM 2576
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 341
Cable > Communication, Control and Industrial > Multipair > Overall Foil Shield > 300 V
Communication and Control
300 V Overall Foil Shield, Multipair, SR-PVC, PVC
UL AWM 2464
UL CM
CSA CMG FT4
Operating Temperature
-20°C to +80°C (AWM)
-20°C to +75°C (CM)
-20°C to +60°C (CMG)
Conductor Color Coding
Chart K (page 529)
Materials
Stranded tinned copper
conductors
Semirigid PVC insulation
Aluminum/polyester foil shield,
25% overlap min.
Foil facing inward
Stranded tinned copper drain
wire equal in size to conductor
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
24 AWG (0.23 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Pairs Nominal Diameter Jacket Thickness
Inch mm Inch mm
5471C 1 0.156 3.96 0.032 0.81
5472C 2 0.212 5.38 0.032 0.81
5473C 3 0.224 5.69 0.032 0.81
5474C 4 0.243 6.17 0.032 0.81
5475C 5 0.270 6.86 0.035 0.89
5476C 6 0.292 7.42 0.035 0.89
5477C 7 0.292 7.42 0.035 0.89
5478C 8 0.316 8.03 0.035 0.89
5479C 9 0.343 8.71 0.037 0.83
5480C 10 0.373 9.47 0.040 1.02
5480/15C 15 0.415 10.54 0.040 1.02
5480/19C 19 0.445 11.30 0.040 1.02
5480/25C 25 0.527 13.39 0.045 1.14
5480/50C * 50 0.699 17.75 0.053 1.35
*Color code chart C.
Individually Shielded, 22 AWG (0.35 mm2), 7/30 (7 x .025) Tinned Copper Drain Wire
UL VW-1
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.33 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Pairs Nominal Diameter Jacket Thickness
Inch mm Inch mm
6416 2 0.295 7.49 0.041 1.04
Mutual capacitance: 55 pF/ft (180 pF/m)
Ground capacitance: 95 pF/ft (312 pF/m)
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
342
Cable > Communication, Control and Industrial > Multipair > Overall Foil Shield > 300 V
Communication and Control
300 V Overall Foil Shield, Multipair, PVC, PVC
UL AWM 2464 VW-1
UL CM
CSA CMG FT4
Operating Temperature
-20°C to +80°C (AWM)
-20°C to +75°C (CM)
-20°C to +60°C (CMG)
Conductor Color Coding
Chart K (page 529)
Materials
Solid tinned copper conductors
PVC insulation
Aluminum/polyester foil shield,
25% overlap min.
Foil facing inward
Stranded tinned copper drain
wire equal in size to conductor
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
22 AWG (0.32 mm2)
Stranding: Solid
Insulation thickness: 0.013 (0.33 mm)
Part No. Pairs Nominal Diameter Jacket Thickness
Inch mm Inch mm
5902C 2 0.238 6.05 0.032 0.81
5905C 4 0.273 6.93 0.032 0.81
5906C 6 0.329 8.36 0.035 0.89
5909C 9 0.385 9.78 0.037 0.94
5909/15C 15 0.471 11.96 0.040 1.02
5909/19C 19 0.506 12.85 0.040 1.02
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 343
Cable > Communication, Control and Industrial > Multipair > Overall Foil Shield > 150 and 300 V
Communication and Control
150 and 300 V Overall Foil Shield, Multipair, PVC, PVC
UL AWM 2576 VW-1 (150 V)
UL AWM 2464 VW-1 (300 V)
UL CM
CSA CMG FT4
Operating Temperature
-20°C to +80°C (AWM)
-20°C to +75°C (CM)
-20°C to +60°C (CMG)
Conductor Color Coding
Chart A (page 528)
Materials
Stranded tinned copper
conductors
PVC insulation
Aluminum/polyester foil shield,
25% overlap min.
Foil facing outward
Stranded tinned copper drain
wire equal in size to conductor
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Pairs Nominal Diameter Jacket Thickness
Inch mm Inch mm
2211C 1 0.168 4.27 0.032 0.81
2212C 2 0.232 5.89 0.032 0.81
2213C 3 0.245 6.22 0.032 0.81
2214C 4 0.266 6.76 0.032 0.81
2215C 5 0.290 7.37 0.032 0.81
2216C 6 0.315 8.00 0.032 0.81
2219C 9 0.372 9.45 0.035 0.89
2219/12C 12 0.415 10.54 0.035 0.89
2219/15C 15 0.451 11.46 0.035 0.89
2219/19C 19 0.494 12.55 0.040 1.02
2219/23C 23 0.545 13.84 0.040 1.02
2219/27C 27 0.589 14.96 0.040 1.02
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Pairs Nominal Diameter Jacket Thickness
Inch mm Inch mm
2241C 1 0.226 5.74 0.032 0.81
2242C 2 0.333 8.46 0.035 0.89
2243C 3 0.357 9.07 0.037 0.94
2244C 4 0.397 10.08 0.040 1.02
2245C 5 0.445 11.30 0.045 1.14
2246C 6 0.485 12.32 0.045 1.14
2249C 9 0.585 14.86 0.055 1.40
2249/12C 12 0.652 16.56 0.055 1.40
2249/19C 19 0.792 20.12 0.070 1.78
300 V, AWM 2464
150 V, AWM 2576
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
344
Cable > Communication, Control and Industrial > Multipair > Overall Foil Shield > 300 V
Communication and Control
300 V Overall Foil Shield, Multipair, PVC, PVC
UL PLTC/CM
UL VW-1
UL Sunlight Resistant
CSA CMG FT4
Operating Temperature
-20°C to +105°C (CM)
-20°C to +60°C (CMG)
Conductor Color Coding
Black and red pairs, numbered
Materials
Stranded tinned copper
conductors
PVC insulation
Aluminum/polyester foil shield,
25% overlap min.
Foil facing inward
Stranded tinned copper drain
wire, 24 AWG (0.22 mm2),
7/32 (7 x 0.20)
Slate PVC jacket
Availability
500 ft (152 m)
1000 ft (305 m)
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.013 (0.33 mm)
Part No. Pairs Nominal Diameter Jacket Thickness
Inch mm Inch mm
6417 2 0.267 6.78 0.038 0.97
6418 3 0.291 7.39 0.043 1.09
6419 4 0.315 8.00 0.043 1.09
6420 6 0.370 9.40 0.043 1.09
6421 9 0.447 11.35 0.053 1.35
6422 11 0.480 12.19 0.053 1.35
6423 15 0.545 13.84 0.053 1.35
6424 19 0.593 15.06 0.063 1.60
6425 27 0.698 17.73 0.063 1.60
6426 51 0.914 23.22 0.075 1.91
18 AWG (0.96 mm2)
Stranding: 19/30 (19 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Pairs Nominal Diameter Jacket Thickness
Inch mm Inch mm
6427 2 0.362 9.19 0.043 1.09
6428 3 0.403 10.24 0.053 1.35
6429 4 0.438 11.13 0.053 1.35
6430 6 0.518 13.16 0.053 1.35
6431 9 0.622 15.80 0.063 1.60
6432 11 0.671 17.04 0.063 1.60
6433 15 0.751 19.08 0.063 1.60
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 345
Cable > Communication, Control and Industrial > Multipair > Overall Foil Shield > 300 V
Communication and Control
300 V Overall Foil Shield, Multipair, HDPE, PVC
Low Capacitance, Extended Distance Cable
UL AWM 2919 (30 V) VW-1
UL CM
CSA CMG FT4
Operating Temperature
-20°C to +80°C (AWM)
-20°C to +75°C (CM)
-20°C to +60°C (CMG)
Conductor Color Coding
Chart M (page 530)
Materials
Stranded tinned copper
conductors
High-density polyethylene
insulation
Aluminum/polyester/aluminum
foil shield, 25% overlap min.
Stranded tinned copper drain
wire equal in size to conductor
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
24 AWG (0.22 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Pairs Nominal Diameter Jacket Thickness
Inch mm Inch mm
6083C 3 0.235 5.97 0.035 0.89
6084C 4 0.254 6.45 0.035 0.89
6087C 7 0.297 7.54 0.035 0.89
6089C 9 0.342 8.69 0.035 0.89
6089/18C 18 0.440 11.18 0.035 0.89
Characteristic impedance: 100 ohms
Mutual capacitance: 15 pF/ft (49.2 pF/m)
Ground capacitance: 27 pF/ft (88.6 pF/m)
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
346
Cable > Communication, Control and Industrial > Multipair > Overall Foil Shield > 300 V
Communication and Control
300 V Overall Foil Shield, Multipair, PE, PVC
Low Capacitance Data Cable
UL AWM 2919 (30 V) VW-1
UL CM
CSA CMH FT1
Operating Temperature
-20°C to +80°C (AWM)
-20°C to +75°C (CM)
-20°C to +60°C (CMH)
Conductor Color Coding
Chart M (page 530)
Materials
Stranded tinned copper
conductors
Polyethylene insulation
Aluminum/polyester foil shield,
25% overlap min.
Foil facing outward
Stranded tinned copper drain
wire equal in size to conductor
Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
24 AWG (0.22 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Pairs Nominal Diameter Jacket Thickness
Inch mm Inch mm
6301 6 0.351 8.92 0.035 0.89
6304 12.5 0.455 11.56 0.035 0.89
Characteristic impedance: 120 ohms
Mutual capacitance: 12.8 pF/ft (42 pF/m)
Ground capacitance: 23 pF/ft (75.4 pF/m)
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 347
Cable > Communication, Control and Industrial > Multipair > Overall Foil Shield > 300 V
Communication and Control
300 V Overall Foil Shield, Multipair, FPP, PVC
Low Capacitance Data Cable
UL AWM 2919 (30 V) VW-1
UL CM
CSA CMG FT4
Operating Temperature
-20°C to +80°C (AWM)
-20°C to +75°C (CM)
-20°C to +60°C (CMG)
Conductor Color Coding
Chart A (page 528)
Materials
Stranded tinned copper
conductors
Foam polypropylene insulation
Aluminum/polyester foil shield,
25% overlap min.
Foil facing outward
Stranded tinned copper drain
wire equal in size to conductor
Slate PVC jacket
Availability
500 ft (152 m)
1000 ft (305 m)
24 AWG (0.22 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Pairs Nominal Diameter Jacket Thickness
Inch mm Inch mm
6202C 2 0.258 6.55 0.035 0.89
6203C 3 0.272 6.91 0.035 0.89
6204C 4.5* 0.304 7.72 0.035 0.89
6205C 5 0.323 8.20 0.035 0.89
6206C 6 0.351 8.92 0.035 0.89
6207C 7 0.351 8.92 0.035 0.89
6208C 8 0.379 9.63 0.035 0.89
6209C 9 0.408 10.36 0.035 0.89
6210C 10 0.441 11.20 0.035 0.89
6210/12C 12.5* 0.455 11.56 0.035 0.89
6210/15C 15 0.496 12.60 0.035 0.89
6210/18C 18.5* 0.554 14.07 0.050 1.27
6210/25C 25 0.655 16.64 0.050 1.27
Characteristic impedance: 105 ohms
Mutual capacitance: 12.5 pF/ft (41 pF/m)
Ground capacitance: 22 pF/ft (72 pF/m)
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.020 (0.51 mm)
Part No. Pairs Nominal Diameter Jacket Thickness
Inch mm Inch mm
6212C 2 0.304 7.72 0.035 0.89
6213C 3 0.322 8.18 0.035 0.89
6216C 6 0.420 10.67 0.035 0.89
6217C 7 0.420 10.67 0.035 0.89
6218C 8 0.456 11.58 0.035 0.89
6220C 10 0.563 14.30 0.050 1.27
6220/12C 12.5* 0.580 14.73 0.050 1.27
6220/15C 15 0.631 16.03 0.050 1.27
6220/18C 18.5* 0.667 16.94 0.050 1.27
6220/25C 25 0.793 20.